12 OPERATION AND INSTALLATION INSTRUCTIONS MN280075EN July 2018Form 6 microprocessor-based rack-mount recloser controlTB1123 5 7 9 11 13 15 17 194 6 8 10 12 14 16 18CI1 CI2 CI3 SS1 CO1 CO2 CO3 CO4CI4CI1 CI2 CI3 SS1 CO1 CO2 CO3 CO4TB3 1 3 5 7 9 11 13 15 17 19 21CI5 CI6 CI7 CI8 CI9 CI10 CI11 CO5 CO6TB42 4 6 8 10 12 14 16 18 20CI4 CI5 CI6 CI7 CI8 CI9 CI10 CI11 CO5 CO61 3 5 7 9 11 13CO7 CO8 CO9 CO10 CO11 CO122 4 6 8 10 12CO7 CO8 CO9 CO10 CO11 CO12FUSE(10 AMP)FUSE(10 AMP)TB5+1-52- 4+INPUT POWER AUXILIARY POWER28 VDCRECLOSER INTERFACE CONNECTIONSA1D3F5 72B4C6ETB6TB2 •1 2•3 4•5 6•7 8•9 10•11 12•13 14•15 16•17 18•19 20I (1-2) I(3-4) I(5-6) V(1-2) V(3-4) V(5-6) V1I(SEF)Three Control Inputand Five StatusOutput Contacts(Standard Feature)Eight Control Inputsand Eight StatusOutputs (Accessory)Fuses125 VDC10 AmpVDC Power InputConnections28 VDC AuxiliaryPower ConnectionsRecloser InterfaceTerminal BlockAnalog ConnectionsTerminal Block forConnecting to Recloser,Voltage InputsJ1-RS-232IRIG-BRS-485RS-232 DTERS-232 Serial Communication PortFiber Optic port, "ST" Type Connector (optional),Ethernet Port, "MT-RJ" Fiber RJ45 Connector (optional)RS-485 Serial Communication Port (optional)C + –IRIG-B Time Sync ConnectorFigure 7 Rack mount control back panelInstallation procedureInitial programming prior to installationCAUTIONEquipment misoperation Do not connect this controlto an energized recloser until all control settings havebeen properly programmed and verified Refer to theprogramming information for this control Failure tocomply can result in control and recloser misoperation,equipment damage, and personal injury G110 3IMPORTANTEquipment misoperation. Check minimum trip values priorto changing an alternate profile. Failure to do so may causemisoperation of the recloser under load conditions. T280.1IMPORTANTProgram all protection profiles. Unused alternate profilesshould be programmed with the same settings as one ofthe applicable profiles. Default settings on unused alternateprofiles can cause unnecessary outages if they are belownormal system requirements.The control must be programmed with all necessaryoperating settings, all alternate profiles, and parametersprior to operation with an energized recloser.otee:N Initial programming of the control is the responsibilityof a qualified technician or engineer familiar withcontrol functions and programming parametersrequired for the specific recloser installation.The control must be programmed with the Form 6 ProViewinterface software. Refer to Service Information S280-70-4(ProView 4.X.X) or S280-70-21 (ProView 5.X.X) Form 6Control Programming Guide for additional information.Control/recloser compatibilityThe Form 6 rack mount recloser control is adaptable to thefollowing Eaton Cooper Power series reclosers:WE*, WVE27, WVE38X, VWE, VWVE27, VWVE38X,VSA12, VSA16, VSA20, VSA12B, VSA20A, VSO12, VSO16,Auxiliary-Powered NOVA reclosers.* This control is not compatible with Form 1 Type WEreclosers below s/n 300 and RE reclosers below s/n 400.IMPORTANTAll Auxiliary-Powered NOVA reclosers require power at theinput power receptacle for tripping and closing.A new control cable is required to connect the Form 6 rackmount recloser control to these reclosers. Refer to Table 3in the Recloser connections/control cable Section of theCustomer connections for DC power and AC voltagesensing section of this manual.