1OPERATION AND INSTALLATION INSTRUCTIONS MN280075EN July 2018Form 6 microprocessor-based rack-mount recloser controlProduct informationIntroductionService Information MN280075EN provides installation andoperation instructions for the Form 6 microprocessor-basedrack mount recloser control above serial number 20,000 orbeginning with CP57.Refer to the following information as appropriate for yourversion of ProView software:●● Service Information S280-70-4 Form 6 Recloser ControlProgramming Guide: ProView 4.X.X software●● Service Information S280-70-21 Form 6 Recloser ControlProgramming Guide: ProView 5.X.X softwareRead this manual firstRead and understand the contents of this manual and followall locally approved procedures and safety practices beforeinstalling or operating this equipment.Additional informationThese instructions cannot cover all details or variationsin the equipment, procedures, or process described, norprovide directions for meeting every possible contingencyduring installation, operation, or maintenance. Whenadditional information is desired to satisfy a problem notcovered sufficiently for the user’s purpose, contact yourEaton representative.ANSI standardsEaton’s Cooper Power series reclosers are designed andtested in accordance with the following ANSI standards:C37.60 and C37.85 and ANSI Guide C37.61.Quality standardsISO 9001-Certified Quality Management SystemAcceptance and initial inspectionEach Form 6 rack mount recloser control is completelyassembled, tested, and inspected at the factory. It iscarefully calibrated, adjusted and in good condition whenaccepted by the carrier for shipment.Upon receipt, inspect the carton for signs of damage.Unpack the control and inspect it thoroughly for damageincurred during shipment. If damage is discovered, file aclaim with the carrier immediately.Handling and storageBe careful during handling and storage of the control tominimize the possibility of damage. If the control is to bestored for any length of time prior to installation, provide aclean, dry storage area. If storage is in a humid atmosphere,make provisions to keep the control circuitry energized.Control powerAll operating power is obtained from the substation batterybank. There are two power supply options available for theForm 6 rack mount recloser control. Examine the voltagedecal on the back of the recloser control to verify thecorrect voltage rating.The following power supply options are available andconfigured at the factory:●● 24 VDC ±20%Burden 14 Watts●● 40 VDC –140 VDCBurden 14 Wattsotee:N The 40 VDC – 140 VDC power supply is a universalpower supply adaptable for either 48 VDC or 125 VDCsubstation batteries.Refer to the Customer connections for DC power andAC voltage sensing section of this manual for incomingpower wiring illustrations for the Form 6 rack mountrecloser control.Form 6 recloser control descriptionDescriptionThe Form 6 rack mount microprocessor-based reclosercontrol includes extensive system protection functionality,including phase, ground, and negative sequence overcurrentprotection, over/underfrequency, and voltage protection,directionality, sensitive ground fault, and sync check.Analysis tools include fault locating, event recording, TCCEditor II, Idea Workbench, and oscillography functions,including oscillography replay.Metering functions include demand and instantaneouscurrent on a per-phase basis, instantaneous voltageand power factor on a per-phase basis, and power (real,reactive, apparent).The front panel LCD display is used to configure theoperating settings for the control. It is also used to displaymetering, counter information, control parameters, resetalarms, and provide diagnostic information.Control parameters can also be programmed via a personalcomputer connected to the control through the front panelRS-232 port. Control programming, interrogation, andoperations are performed with Form 6 ProView interfacesoftware on a personal computer.The interface program software includes additional functionsused to create and graphically display Time Current Curvesand provide Idea Workbench for configuring user-selectedinputs and outputs, configurable event and alarm data, andselectable communication points for serial communication.The control operates on 50 and 60 Hz systems.