20 GREEN MOTION DC 44/66 EV CHARGER INSTALLATION MANUAL MN192006EN March 2023 www.eaton.com00 TitleEaton recommends the use of the equipment in Table 7 as protective devices.Table 7. Eaton recommendations for protective devices for Green Motion DC 44/66 EV chargerA d detailed connection diagram of the Green Motion DC 22 EV charger in Figure 20 shows the main components,including the input switch, EMI filter, surge protection, power module, and the charging outputs. the power modulesand the charging outputs. The third 22 kV power module (PM) is represented by a dashedYeYeah line, which means thatit is only available in the Green Motion DC 66 EV charger version.Figure 12. Detailed connection diagram of the EV chargerTag Description1 EMI filter2 Auxiliary control3 AC-DC power modules4 Input, 3 x 400 VAC5 Output, CHAdeMOOutput, CCSCHAdeMO/CCS control interfaceGreen Motion DC 44 Green Motion DC 66Type of protective device 80 A breaker for 3-phase 64 Acharging current125 A breaker for 3-phase 96 Acharging currentEaton product recommendation AZ-3N-C80 AZ-3N-C125Article number 211803 211813SQ1L1 L2 L3 NSPDF1L2 NPEA1 A2 RisoPEPEL1 L2 L3 NPM122 kWNL3L2L1PM322 kWPM122 kWMCB1 MCB2 MCB3CHAdeMOCSS2CHAdeMO/CSS2 CTRLPENL3L2L1 NL3L2L112354 6677