2 GREEN MOTION DC 44/66 EV CHARGER INSTALLATION MANUAL MN192006EN March 2023 www.eaton.com00 Title1.1 Field of applicationsThis installation manual is intended for professional and qualified personnel. It describes how to securely install andcommission the Eaton Green Motion DC 44 and the Eaton Green Motion DC 66 EV chargers:Table 1. Eaton Green Motion DC 44/66 EV charger overviewPower inputInput voltage AC 3 x 400 V, 50 Hz 3 x 400 V, 50 HzNominal input current AC 3 x 64 A (44 kW) 3 x 96 A (66 kW)Power factor > 0.99 > 0.99Phase 3 Phase 3 phaseEarthing system TN, TT TN, TTPower outputNominal output power 44 kW 66 kWOutput voltage for the DC range 50 V - 500 V 50 V - 500 VOutput current DC at nominal power 110 A 165 AOutput type - CCS 2 (default)- CCS 2 and CHAdeMO (optional)- CCS 2 (default)- CCS 2 and CHAdeMO (optional)Efficiency ≤ 96% ≤ 96%Simultaneous charging 1 1OptionsCable 1 x CHAdeMO 1 x CHAdeMONetwork interface 3G/4G 3G/4GSoftware licenses Eaton Scan & ChargeEaton Charging network managerEaton Scan & ChargeEaton Charging network managerWarrantyWarranty 2 years 2 yearsRead the instructions. These instructions are intended for professional installers. Professional and qualifiedpersonnel must be an expert in the field and is therefore responsible for commissioning the system inaccordance with the manufacturer’s instructions and local legislation.An electric shock can be fatal.Avoid touching internal or external parts normally live while the system is powered on.1.2 Symbols used in this manualHazardous behaviors that could cause serious injuries.Hazardous behaviors that could cause death.Imminent dangers causing serious injuries. Danger of death.Behaviors that could cause minor injuries to people or minor damages to things.1.2.1 Related icons