- INTRODUCTION
- Single UPM and Two UPM Configurations
- Figure 1-2. 600V 2x UPM Configuration
- Single UPM Plus 1 UPM Configuration
- UPS Standard Features
- Advanced Battery Management
- Distributed Bypass System
- Energy Saver and High Alert Modes
- Battery System
- Using This Manual
- Symbols, Controls, and Indicators
- Getting Help
- SAFETY WARNINGS
- UPS INSTALLATION PLAN AND UNPACKING
- Installation Considerations
- V, 400V, 415V, and 480V Model Configurations
- Figure 3-1. Single UPM Configuration Dimensions
- Figure 3-2. Single UPM Configuration, Plus 1 FI-UPM (Dimensions)
- Figure 3-3. Two UPM Configuration (Dimensions)
- V Model Configurations
- Figure 3-5. 600V Single UPM Configuration, Plus 1 FI-UPM
- Figure 3-6. 600V Two UPM Configuration
- Figure 3-7. Side View Dimensions and Center of Gravity Measurements
- UPS System Power Wiring Preparation
- UPS System Interface Wiring Preparation
- Distributed Bypass Power Wiring Preparation
- Figure 3-8. Single UPM Configuration as Shipped on Pallet (380V, 400V, 415V, and 480V)
- Figure 3-9. Two UPM Configuration as Shipped on Pallet (380V, 400V, 415V, and 480V)
- INSTALLATION
- Figure 4-1. Removing the ISBM Section Left Side Shipping Bracket
- Figure 4-2. Removing the ISBM Section Right Side Shipping Bracket
- Mechanically Joining the Sections (600V Models Only)
- Figure 4-4. ISBM and UPM Sections Joined
- Figure 4-5. ISBM Section to UPM Section Joining Brackets
- Electrically Connecting the Sections (600V Models Only)
- Figure 4-6. UPS Intercabinet Interface Harness Locations
- Connecting Intercabinet CAN Cables and Connectors
- Figure 4-8. Pl1 Interface Board Location
- Field Installed UPM Installation
- Installing UPS External and Battery Power Wiring
- External Power Wiring Installation
- Figure 4-12. ISBM and UPM Section Conduit and Wire Entry Locations
- Figure 4-13. Distributed Bypass Wire Length
- Figure 4-14. ISBM Section Power Terminal Locations (380V, 400V, 415V, and 480V Models)
- Figure 4-15. ISBM Section Power Terminal Locations (600V Models)
- Figure 4-16. ISBM Section Power Terminal Detail – Section AA (380V, 400V, 415V, and 480V Models)
- Battery Power Wiring
- Installing Interface Connections
- TB1, TB2, and TB3 Connections (Other than TB1 Battery Interface Connections)
- Figure 4-18. ISBM Section Interface Terminal Locations
- Figure 4-19. Interface Terminal Detail
- Figure 4-21. Terminal Blocks TB1, TB2, and TB3 Connector Assignments
- TB1 Battery Interface Connections
- Figure 4-22. Typical Battery Interface Connection – Common Battery System
- X-Slot Connections
- Installing a REPO Switch
- Figure 4-26. REPO Switch
- Figure 4-27. Normally-Open REPO Switch Wiring
- Figure 4-28. Normally-Closed REPO Switch Wiring
- Installing Options, Accessories, and Distributed Bypass Control Wiring
- INSTALLATION CHECKLIST
- DISTRIBUTED BYPASS INSTALLATION CHECKLIST
- INSTALLING OPTIONS AND ACCESSORIES
- Installing an Optional Hot Sync CAN Bridge Card
- Figure 5-2. Hot Sync CAN Bridge Card Connections
- Installing Distributed Bypass Control Wiring
- Figure 5-3. Distributed Bypass System CAN and Pull-Chain Simplified Interface Wiring
- Figure 5-5. Distributed Bypass Pull-Chain Wiring without MOBs
- Figure 5-6. Distributed Bypass Pull-Chain Wiring with MOBs
- Installing an Optional Remote Monitor Panel II
- Figure 5-7. Remote Monitor Panel II and Relay Interface Module II Terminal Locations
- Figure 5-8. Remote Monitor Panel II, Relay Interface Module II, or Supervisory Contact Module II Wiring
- Installing an Optional Relay Interface Module II
- Installing an Optional Supervisory Contact Module II
- Figure 5-10. Supervisory Contact Module II Terminal Location
- Accessory Mounting Dimensions
- Figure 5-12. Remote Monitor Panel II Dimensions
- Figure 5-13. Relay Interface Module II Dimensions
- Figure 5-14. Supervisory Contact Module II Dimensions
- UNDERSTANDING UPS OPERATION
- Single UPS
- Figure 6-2. Path of Current Through the UPS in Online Mode
- Energy Saver System (ESS) Mode
- Bypass Mode
- Battery Mode
- Figure 6-4. Path of Current Through the UPS in Battery Mode
- Single UPS Unit System Oneline Configurations
- Figure 6-5. One UPM, Rectifier Feed, Battery System, Dual-Feed Configuration, Continuous Static Switch
- Figure 6-6. One UPM, Common Rectifier Feed, Common Battery, Dual-Feed Configuration, Continuous Static Switch FI-UPM
- Figure 6-7. One UPM, Common Rectifier Feed, Separate Battery, Dual-Feed Configuration, Continuous Static Switch FI-UPM
- Figure 6-8. Two UPM, Common Rectifier Feed, Common Battery, Dual-Feed Configuration, Continuous Static Switch
- Figure 6-9. Two UPM, Common Rectifier Feed, Separate Battery, Dual-Feed Configuration, Continuous Static Switch
- Figure 6-10. One UPM, Rectifier Feed, Battery System, IOM Configuration
- Figure 6-11. One UPM, Common Rectifier Feed, Common Battery, IOM Configuration, FI-UPM
- Figure 6-12. One UPM, Common Rectifier Feed, Separate Battery, IOM Configuration, FI-UPM
- Figure 6-13. Two UPM, Common Rectifier Feed, Common Battery, IOM Configuration
- Figure 6-14. Two UPM, Common Rectifier Feed, Separate Battery, IOM Configuration
- Figure 6-15. Simplified Dual-Feed UPS with Maintenance Bypass Panel
- Multiple UPS Distributed Bypass System
- Online Mode - Distributed Bypass
- Bypass Mode – Distributed Bypass
- Battery Mode - Distributed Bypass
- Figure 6-18. Path of Current through the UPSs in Battery Mode - Distributed Bypass
- Multiple UPS Distributed Bypass System Oneline Configurations
- Figure 6-19. Typical Distributed Bypass System - Continuous Static Switch, 1+1 and 2+0 Configurations
- Figure 6-20. Typical Distributed Bypass System -Continuous Static Switch, 2+1 and 3+0 Configurations
- Figure 6-21. Typical Distributed Bypass System -Continuous Static Switch, 3+1 and 4+0 Configurations
- UPS OPERATING INSTRUCTIONS
- Circuit Breakers
- Status Indicators
- Figure 7-3. Parts of the Touch Screen
- Figure 7-4. Sign In or Password Request Screen
- Using the Main Menu Buttons
- Power Maps Screen (Online Mode)
- Figure 7-8. Average Efficiency Screen from Home Screen
- Power Maps Screen (Bypass Mode)
- Meters Summary Screen
- Input Meters Screen
- Figure 7-15. Output Meters Screen
- Input Meters Detail Screen
- Battery Meters Screens
- Figure 7-20. Battery Log Detail
- System Events Main Screen
- Figure 7-23. User Log Screen
- System Status Screen and Controls
- Figure 7-27. Module Control Detail Screen
- Settings Screen
- Configuration Options Screen
- Figure 7-33. Disable ESS Screen
- Statistics Basic Screen
- ESS Comparison Screen
- System Overview Screen
- UPS Operation using the Color Touchscreen Control Panel
- Using the Remote Emergency Power-off Switch
- Figure 7-40. REPO Operation
- Multiple UPS Distributed Bypass Operation
- Starting the Distributed Bypass System in Bypass Mode
- Single UPM Shutdown
- Single UPS Shutdown using Load Off
- Single UPS Shutdown using UPM Shutdown
- Single UPS Restart
- UPS and Critical Load Shutdown
- Using the UPS LOAD OFF Pushbutton
- Using the UPS LOAD OFF Command
- COMMUNICATION
- PredictPulse
- Power Management Software
- Remote Monitor Panel II
- Relay Interface Module II
- Supervisory Contact Module II
- UPS MAINTENANCE
- Performing Preventive Maintenance
- Figure 9-1. ISBM and UPM Section Air Filter Locations - Continuous Static Switch
- Figure 9-2. FI-UPM Air Filter Location
- PERIODIC Maintenance
- Installing Batteries
- Maintenance Training
- PRODUCT SPECIFICATIONS
- UPS Output
- UPS Environmental
|
Introduction1-6 Eaton ® Power Xpert® 9395P-300 (300kVA, 300kW) UPS Installation and Operation Manual P-164000563—Rev 04 www.eaton.com/powerqualityl Alarm Contact. One alarm contact is provided for connection to equipment at the facility, such as a light, anaudible alarm, or a computer terminal. The equipment connected to this contact alerts you to a UPS alarm.See Chapter 8, “Communication” for additional information.l X-Slot Communication Bays. Four communication bays are standard equipment. One to four optional X-Slotsinline (for generic slot name; ie: Avaya's alarm adapter) connectivity cards can be installed in the UPSmodule at any time. X-Slot cards are quickly installed at the front of the UPS and are hot-pluggable. SeeChapter 8, “Communication” for additional information.1.3.4 Advanced Battery ManagementA three-stage charging system increases battery service life by optimizing recharge time, and protects batteriesfrom damage due to high current charging and inverter ripple currents. Charging at high currents can overheatand damage batteries.1.3.5 Power Management SoftwareIntelligent Power Management and Intelligent Power Protector software are available through Eaton support.See Chapter 8, “Communication” for additional information.1.4 Options and AccessoriesContact an Eaton sales representative for information about the following options.1.4.1 Integrated Battery CabinetsBattery backup protection can be provided by equipping the UPS system with 9395P-300 battery cabinetscontaining sealed lead-acid, maintenance-free batteries. The cabinets are designed for standalone installationand may be installed adjacent to the UPS or in a separate location. The recommended installation location foradjacent battery cabinets is on the right side of the UPS cabinet to allow for future expansion using an externalmodule.Consult the Eaton® Power Xpert ® 9395/9395P Integrated Battery Cabinet (Models 1085 and 1085HR)Installation Manual (P-164000580) for specifics on battery cabinet usage with the 9395P-300.1.4.2 Field Installed UPMA Field Installed UPM (FI-UPM) provides redundancy for the 9395P-300. The FI-UPM may be installed at anytime in the future. The module cabinet is installed on the left side of the ISBM section and is wired directly tothe UPS. No input or output wiring changes are needed for adding redundancy. Operation remains the sameas the original UPS. Each UPM is rated for a maximum of 300 kVA.Refer to the Eaton® Power Xpert ® 9395P UPS Field Installed UPM Mechanical Installation Manual(P-164000503) for specifics on the FI-UPM usage with the 9395P-300.1.4.3 Sync ControlAn optional 9395P-300 Sync Control maintains the critical load outputs of two separate single module9395P-300 UPS systems in synchronization. This option facilitates the uninterrupted transfer of the load fromone load bus to another by means of transfer switches. The Sync Control is housed in a wall-mounted panelthat can be located between the UPS units for easy wiring.Refer to the Eaton ® Power Xpert ® 9395P Sync Control Installation and Operation Manual (P-164000502) forspecifics on battery cabinet usage with the 9395P-300.1.4.4 Single-Feed KitAn optional kit is available for converting the dual-feed rectifier and bypass inputs to a single-feed configuration.The kit consists of jumpers and bus bar extensions for each phase, and the hardware required for installation. PreviousNext |