Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- INTRODUCTION
- Single UPM and Two UPM Configurations
- Figure 1-2. 600V 2x UPM Configuration
- Single UPM Plus 1 UPM Configuration
- UPS Standard Features
- Advanced Battery Management
- Distributed Bypass System
- Energy Saver and High Alert Modes
- Battery System
- Using This Manual
- Symbols, Controls, and Indicators
- Getting Help
- SAFETY WARNINGS
- UPS INSTALLATION PLAN AND UNPACKING
- Installation Considerations
- V, 400V, 415V, and 480V Model Configurations
- Figure 3-1. Single UPM Configuration Dimensions
- Figure 3-2. Single UPM Configuration, Plus 1 FI-UPM (Dimensions)
- Figure 3-3. Two UPM Configuration (Dimensions)
- V Model Configurations
- Figure 3-5. 600V Single UPM Configuration, Plus 1 FI-UPM
- Figure 3-6. 600V Two UPM Configuration
- Figure 3-7. Side View Dimensions and Center of Gravity Measurements
- UPS System Power Wiring Preparation
- UPS System Interface Wiring Preparation
- Distributed Bypass Power Wiring Preparation
- Figure 3-8. Single UPM Configuration as Shipped on Pallet (380V, 400V, 415V, and 480V)
- Figure 3-9. Two UPM Configuration as Shipped on Pallet (380V, 400V, 415V, and 480V)
- INSTALLATION
- Figure 4-1. Removing the ISBM Section Left Side Shipping Bracket
- Figure 4-2. Removing the ISBM Section Right Side Shipping Bracket
- Mechanically Joining the Sections (600V Models Only)
- Figure 4-4. ISBM and UPM Sections Joined
- Figure 4-5. ISBM Section to UPM Section Joining Brackets
- Electrically Connecting the Sections (600V Models Only)
- Figure 4-6. UPS Intercabinet Interface Harness Locations
- Connecting Intercabinet CAN Cables and Connectors
- Figure 4-8. Pl1 Interface Board Location
- Field Installed UPM Installation
- Installing UPS External and Battery Power Wiring
- External Power Wiring Installation
- Figure 4-12. ISBM and UPM Section Conduit and Wire Entry Locations
- Figure 4-13. Distributed Bypass Wire Length
- Figure 4-14. ISBM Section Power Terminal Locations (380V, 400V, 415V, and 480V Models)
- Figure 4-15. ISBM Section Power Terminal Locations (600V Models)
- Figure 4-16. ISBM Section Power Terminal Detail – Section AA (380V, 400V, 415V, and 480V Models)
- Battery Power Wiring
- Installing Interface Connections
- TB1, TB2, and TB3 Connections (Other than TB1 Battery Interface Connections)
- Figure 4-18. ISBM Section Interface Terminal Locations
- Figure 4-19. Interface Terminal Detail
- Figure 4-21. Terminal Blocks TB1, TB2, and TB3 Connector Assignments
- TB1 Battery Interface Connections
- Figure 4-22. Typical Battery Interface Connection – Common Battery System
- X-Slot Connections
- Installing a REPO Switch
- Figure 4-26. REPO Switch
- Figure 4-27. Normally-Open REPO Switch Wiring
- Figure 4-28. Normally-Closed REPO Switch Wiring
- Installing Options, Accessories, and Distributed Bypass Control Wiring
- INSTALLATION CHECKLIST
- DISTRIBUTED BYPASS INSTALLATION CHECKLIST
- INSTALLING OPTIONS AND ACCESSORIES
- Installing an Optional Hot Sync CAN Bridge Card
- Figure 5-2. Hot Sync CAN Bridge Card Connections
- Installing Distributed Bypass Control Wiring
- Figure 5-3. Distributed Bypass System CAN and Pull-Chain Simplified Interface Wiring
- Figure 5-5. Distributed Bypass Pull-Chain Wiring without MOBs
- Figure 5-6. Distributed Bypass Pull-Chain Wiring with MOBs
- Installing an Optional Remote Monitor Panel II
- Figure 5-7. Remote Monitor Panel II and Relay Interface Module II Terminal Locations
- Figure 5-8. Remote Monitor Panel II, Relay Interface Module II, or Supervisory Contact Module II Wiring
- Installing an Optional Relay Interface Module II
- Installing an Optional Supervisory Contact Module II
- Figure 5-10. Supervisory Contact Module II Terminal Location
- Accessory Mounting Dimensions
- Figure 5-12. Remote Monitor Panel II Dimensions
- Figure 5-13. Relay Interface Module II Dimensions
- Figure 5-14. Supervisory Contact Module II Dimensions
- UNDERSTANDING UPS OPERATION
- Single UPS
- Figure 6-2. Path of Current Through the UPS in Online Mode
- Energy Saver System (ESS) Mode
- Bypass Mode
- Battery Mode
- Figure 6-4. Path of Current Through the UPS in Battery Mode
- Single UPS Unit System Oneline Configurations
- Figure 6-5. One UPM, Rectifier Feed, Battery System, Dual-Feed Configuration, Continuous Static Switch
- Figure 6-6. One UPM, Common Rectifier Feed, Common Battery, Dual-Feed Configuration, Continuous Static Switch FI-UPM
- Figure 6-7. One UPM, Common Rectifier Feed, Separate Battery, Dual-Feed Configuration, Continuous Static Switch FI-UPM
- Figure 6-8. Two UPM, Common Rectifier Feed, Common Battery, Dual-Feed Configuration, Continuous Static Switch
- Figure 6-9. Two UPM, Common Rectifier Feed, Separate Battery, Dual-Feed Configuration, Continuous Static Switch
- Figure 6-10. One UPM, Rectifier Feed, Battery System, IOM Configuration
- Figure 6-11. One UPM, Common Rectifier Feed, Common Battery, IOM Configuration, FI-UPM
- Figure 6-12. One UPM, Common Rectifier Feed, Separate Battery, IOM Configuration, FI-UPM
- Figure 6-13. Two UPM, Common Rectifier Feed, Common Battery, IOM Configuration
- Figure 6-14. Two UPM, Common Rectifier Feed, Separate Battery, IOM Configuration
- Figure 6-15. Simplified Dual-Feed UPS with Maintenance Bypass Panel
- Multiple UPS Distributed Bypass System
- Online Mode - Distributed Bypass
- Bypass Mode – Distributed Bypass
- Battery Mode - Distributed Bypass
- Figure 6-18. Path of Current through the UPSs in Battery Mode - Distributed Bypass
- Multiple UPS Distributed Bypass System Oneline Configurations
- Figure 6-19. Typical Distributed Bypass System - Continuous Static Switch, 1+1 and 2+0 Configurations
- Figure 6-20. Typical Distributed Bypass System -Continuous Static Switch, 2+1 and 3+0 Configurations
- Figure 6-21. Typical Distributed Bypass System -Continuous Static Switch, 3+1 and 4+0 Configurations
- UPS OPERATING INSTRUCTIONS
- Circuit Breakers
- Status Indicators
- Figure 7-3. Parts of the Touch Screen
- Figure 7-4. Sign In or Password Request Screen
- Using the Main Menu Buttons
- Power Maps Screen (Online Mode)
- Figure 7-8. Average Efficiency Screen from Home Screen
- Power Maps Screen (Bypass Mode)
- Meters Summary Screen
- Input Meters Screen
- Figure 7-15. Output Meters Screen
- Input Meters Detail Screen
- Battery Meters Screens
- Figure 7-20. Battery Log Detail
- System Events Main Screen
- Figure 7-23. User Log Screen
- System Status Screen and Controls
- Figure 7-27. Module Control Detail Screen
- Settings Screen
- Configuration Options Screen
- Figure 7-33. Disable ESS Screen
- Statistics Basic Screen
- ESS Comparison Screen
- System Overview Screen
- UPS Operation using the Color Touchscreen Control Panel
- Using the Remote Emergency Power-off Switch
- Figure 7-40. REPO Operation
- Multiple UPS Distributed Bypass Operation
- Starting the Distributed Bypass System in Bypass Mode
- Single UPM Shutdown
- Single UPS Shutdown using Load Off
- Single UPS Shutdown using UPM Shutdown
- Single UPS Restart
- UPS and Critical Load Shutdown
- Using the UPS LOAD OFF Pushbutton
- Using the UPS LOAD OFF Command
- COMMUNICATION
- PredictPulse
- Power Management Software
- Remote Monitor Panel II
- Relay Interface Module II
- Supervisory Contact Module II
- UPS MAINTENANCE
- Performing Preventive Maintenance
- Figure 9-1. ISBM and UPM Section Air Filter Locations - Continuous Static Switch
- Figure 9-2. FI-UPM Air Filter Location
- PERIODIC Maintenance
- Installing Batteries
- Maintenance Training
- PRODUCT SPECIFICATIONS
- UPS Output
- UPS Environmental
|
UPS Installation Plan and UnpackingEaton ® Power Xpert® 9395P-300 (300kVA, 300kW) UPS Installation and Operation Manual P-164000563—Rev 04 www.eaton.com/powerquality 3-133.2.5 UPS System Power Wiring PreparationRead and understand the following notes while planning and performing the installation:l Refer to national and local electrical codes for acceptable external wiring practices.l To allow for future kVA upgrades, consider installing a derated UPS using wiring and external overcurrentprotection breakers sized for a fully rated UPS.l For external wiring, use 75°C copper or aluminum wire. Wire sizes listed in Table 3-10 through Table 3-22are for copper wiring only. If wire is run in an ambient temperature greater than 30°C, higher temperaturewire and/or larger size wire may be necessary. Wire sizes are based on using the specified breakers.l Wire ampacities are chosen from Table 310.15(b) (16) of the National Electrical Code (NEC). Specification isfor copper wire with a 75°C rating.l Material and labor for external wiring requirements are to be provided by designated personnel.l If installing a maintenance bypass, a minimum of two separate feeds with upstream feeder breakers, or asingle feed with two upstream feeder breakers, must be provided: one for the UPS or rectifier input breaker(RIB) (if installed) and one for the maintenance bypass input. DO NOT use a single feed or a single feederbreaker to supply both the UPS or RIB and the maintenance bypass. If a bypass input breaker (BIB) isinstalled in the maintenance bypass and a single-feed UPS is being installed, a single feed to themaintenance bypass is acceptable for supplying both the UPS and the bypass.l The bypass and rectifier feeds into this equipment use three wires. The phases must be symmetrical aboutground (from a Wye source) for proper equipment operation.l The Eaton 9395P-300 480V and 600V unit is designed for operation on a grounded-wye source of supply.There is no additional connection point for a neutral conductor. The output of this UPS will not directlysupport phase to neutral loads.l The ISBM and UPM sections are shipped with debris shields covering the ventilation grills on top of thesections. Do not remove the debris shields until installation is complete. However, remove the shieldsbefore operating the UPS. Once the debris shields are removed, do not place objects on the ventilationgrills.l In a common battery system, all UPMs are powered from one common battery source. In a separate batterysystem, each UPM is powered from separate battery sources.l UPSs in distributed bypass and parallel systems must use a separate battery system for each UPS.l On a UPS configured as an Input Output Module (IOM), requirements for bypass input wiring, termination,conduit, and bypass breaker are not applicable.If the power rating listed on the nameplate of the installed UPS is not found in the following tables, wire theUPS using the fully rated specifications. Otherwise, calculate the required wire, conduit, and breaker sizesusing the following guidelines in addition to those already listed in paragraph 3.2.5:l Select wire size according to the UPS nameplate.l Do not use wire larger than the largest size listed in Table 3-6 through Table 3-17.l Use terminal recommendations from Table 3-18 through Table 3-21.l Size and number of conduits must not exceed those listed in Table 3-22 and Table 3-24.l Select overcurrent protection input, battery, and output breakers according to the UPS nameplate rated foreither 80% or 100%.l Follow all applicable NEC and local codes.Wire sizes listed are for copper wiring only PreviousNext |