GE Feeder Management Relay 750 Instruction Manual
7-38 750/760 Feeder Management Relay GE Multilin7.4 MODBUS MEMORY MAP 7 COMMUNICATIONS71BD2 2 Overcurrent Blocking Flags --- --- F59 None blocked1BD3 1 Phase Time Overcurrent 1 Raised Pickup 0 to 100 % F1 0%1BD4 1 Neutral Time Overcurrent 1 Raised Pickup 0 to 100 % F1 0%1BD5 1 Ground Time Overcurrent Raised Pickup 0 to 100 % F1 0%1BD6 1 Negative Sequence Time Overcurrent Raised Pickup 0 to 100 % F1 0%1BD7 3 Sensitive Ground Time Overcurrent Raised Pickup 0 to 100 % F1 0%S7 RECLOSURE SHOT 3 - 760 ONLY READ/WRITE1BE02 Deadtime Before Reclosure 3 0.00 to 300.00 s F3 4.00 s1BE11 Select Setpoint Group --- --- F80 Active Group1BE22 Overcurrent Blocking Flags --- --- F59 None blocked1BE31 Phase Time Overcurrent 1 Raised Pickup 0 to 100 % F1 0%1BE41 Neutral Time Overcurrent 1 Raised Pickup 0 to 100 % F1 0%1BE51 Ground Time Overcurrent Raised Pickup 0 to 100 % F1 0%1BE61 Negative Sequence Time Overcurrent Raised Pickup 0 to 100 % F1 0%1BE73 Sensitive Ground Time Overcurrent Raised Pickup 0 to 100 % F1 0%S7 RECLOSURE SHOT 4 - 760 ONLY READ/WRITE1BF0 2 Deadtime Before Reclosure 4 0.00 to 300.00 s F3 5.00 s1BF11 Select Setpoint Group --- --- F80 Active Group1BF2 2 Overcurrent Blocking Flags --- --- F59 None blocked1BF3 1 Phase Time Overcurrent 1 Raised Pickup 0 to 100 % F1 0%1BF4 1 Neutral Time Overcurrent 1 Raised Pickup 0 to 100 % F1 0%1BF5 1 Ground Time Overcurrent Raised Pickup 0 to 100 % F1 0%1BF6 1 Negative Sequence Time Overcurrent Raised Pickup 0 to 100 % F1 0%1BF7 3 Sensitive Ground Time Overcurrent Raised Pickup 0 to 100 % F1 0%S3 LOGIC INPUTS NAMES READ/WRITE1C00 1 Logic Input 1 Name (9 words = 18 characters) --- --- F33 Logic Input 11C09 1 Logic Input 2 Name (9 words = 18 characters) --- --- F33 Logic Input 2↓ ↓ ↓ ↓ ↓ ↓1CAB 1 Logic Input 20 Name (9 words = 18 characters) --- --- F33 Logic Input 20A4 EVENT RECORD SELECTOR READ/WRITE2000 Event Number Selector 0 to 65535 --- F1 0A4 EVENT RECORDOR INFORMATION READ ONLY2001 Number of Events Since Clear 0 to 65535 --- F1 02002 Event Recorder Last Cleared (2 words) --- --- F23 ---A4 EVENT RECORD DATA READ ONLY2010 Record #N Date of Event (2 words) --- --- F23 ---2012 Record #N Time of Event (2 words) --- --- F22 ---2014 Record #N Cause of Event --- --- F24 ---2015 Record #N Phase A Current Magnitude 0 to 65535 A F1 ---2016 Record #N Phase B Current Magnitude 0 to 65535 A F1 ---2017 Record #N Phase C Current Magnitude 0 to 65535 A F1 ---2018 Record #N Ground Current Magnitude 0 to 65535 A F1 ---2019 Record #N A-N (A-B) Voltage Magnitude 0.00 to 600.00 kV F3 ---201A Record #N B-N (B-C) Voltage Magnitude 0.00 to 600.00 kV F3 ---201B Record #N C-N (C-A) Voltage Magnitude 0.00 to 600.00 kV F3 ---201C Record #N System Frequency 0.00 to 90.00 Hz F3 ---201D Record #N Analog Input 0 to 65535 Units F1 ---201E 1 Record #N Phase A Current Angle 0 to 359 ° Lag F1 ---201F 1 Record #N Phase B Current Angle 0 to 359 ° Lag F1 ---20201 Record #N Phase C Current Angle 0 to 359 ° Lag F1 ---20211 Record #N Ground Current Angle 0 to 359 ° Lag F1 ---20221 Record #N A-N (A-B) Voltage Angle 0 to 359 ° Lag F1 ---20231 Record #N B-N (C-B) Voltage Angle 0 to 359 ° Lag F1 ---Table 7–6: MODBUS MEMORY MAP (SHEET 26 OF 27)ADDR DESCRIPTION RANGE UNITS TYPE DEFAULT1 2 3 4 5 6 7 8 9 For explanation of Table footnotes, see the Memory Map Notes at the end of this table. |
Related manuals for GE Feeder Management Relay 750
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine