Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Specifications
- Hydraulic Oil Specifications
- Hydraulic Component Specifications
- Hydraulic Hose and Fitting Torque Specifications
- Torque Procedure
- Repair Procedures
- Platform Controls
- Circuit Board
- Joystick
- Platfrom Controls Alarm
- Platform Components
- Platform Extension Deck
- Scissor Components
- Scissor Assembly, GS-2669 DC
- Scissor Assembly, GS-3369 DC
- Scissor Assembly, GS-4069 DC
- Wear Pads
- Lift Cylinders
- November
- Ground Controls
- Software Revision Level
- Machine Setup
- Auxiliary Platform Lowering
- Level Sensor - Models with Outriggers
- Service Override Mode
- Hydraulic Pump
- How to Calibrate the Hydraulic Pump
- Manifolds
- a Function Manifold Components
- Valve Adjustments - Function Manifold
- How to Adjust the Oscillate Relief Valve
- How to Adjust the Steer Relief Valve
- How to Adjust the Platform Up Relief Valve - Models without Platform Overload
- Outrigger Manifold Components
- Valve Coils
- Hydraulic Tank
- Steer Cylinder
- Oscillate Cylinder
- Steer Angle Sensor
- Non-steer Axle Components
- Drive Hub
- Outrigger Components
- Outrigger Calibration
- Platform Overload Components
- Platform Overload Recovery
- Fault Codes
- GCON I/O Map
- Operation Indicator Codes (OIC)
- Troubleshooting "HXXX" and "PXXX" Faults
- Fault Inspection Procedure
- Type "HXXX" Faults
- Type "PXXX" Faults
- Type "UXXX" Faults
- Type "FXXX" Faults
- Type "CXXX" Faults
- Section 5 Schematics
- Electrical Schematic Abbreviations and Wire Color Legends
- Hydraulic Component Legend
- Electrical Symbols Legend
- Hydraulic Symbols Legend
- Limit Switch Legend
- Fuse, Ground and Platform Control Boxes
- Fuse Box Layout, All Models
- Ground Control Box Layout, All Models
- Platform Control Box Layout, Models with 2 Speed Lift
- Control Box Layout, Models with Proportional Lift
- Electrical Schematics - ANSI / CSA
- Electrical Schematic, GS-2669 DC and GS-3369 DC with 2 Speed Lift, (ANSI CSA) (to serial number GS6915-6388)
- Electrical Schematic, GS-2669 DC and GS-3369 DC with Proportional Lift, (ANSI CSA) (from serial number GS6915-6389 to GS6915-7719)
- Electrical Schematic, GS-2669 DC and GS-3369 DC with Proportional Lift, (ANSI CSA) (from serial number GS6915-7720)
- Electrical Schematic, GS-4069 DC with 2 Speed Lift, (ANSI / CSA) (to serial number GS6915-6388)
- Electrical Schematic, GS-4069 DC with Proportional Lift, (ANSI / CSA) (from serial number GS6915-7720)
- Electrical Schematics - AS / CE
- Electrical Schematic, GS-2669 DC and GS-3369 DC with 2 Speed Lift, (AS / CE to serial number GS6915-6388)
- Electrical Schematic, GS-2669 DC and GS-3369 DC with Proportional Lift, (AS CE) (from serial number GS6915-6389 to GS6915-7719)
- Electrical Schematic, GS-2669 DC and GS-3369 DC with Proportional Lift, (AS CE) (from serial number GS6915-7720)
- Electrical Schematic, GS-4069 DC with 2 Speed Lift, (AS / CE) (to serial number GS6915-6388)
- Electrical Schematic, GS-4069 DC with Proportional Lift, (AS / CE) (from serial number GS6915-6389 to GS6915-7719)
- Electrical Schematic, GS-4069 DC with Proportional Lift, (AS / CE) (from serial number GS6915-7720)
- Hydraulic Schematics
- Hydraulic Schematic, GS-2669 DC and GS-3369 DC with 2 Speed Lift (to serial number GS6915-6388)
- Hydraulic Schematic, GS-2669 DC and GS-3369 DC with Proportional Lift (from serial number GS6915-6389)
- Hydraulic Schematic, GS-4069 DC with 2 Speed Lift (to serial number GS6915-6388)
- Hydraulic Schematic, GS-4069 DC with Proportional Lift (from serial number GS6915-6389)
|
Service and Repair Manual November 2016Fault Codes98 GS-2669 DC • GS-3369 DC • GS-4069 DC Part No. 1272220GTOperati on Indi cator C odes (OIC)Operation Indicator Codes (OIC)These codes are generated by the electricalsystem to indicate machine operating status suchas Off-level, Overload Cutout, Chassis ModeOperation during normal operation. These codesare not indicators of a device malfunction in theelectrical system.Code ConditionLL Off-LevelOL Platform Overload (CE and Australia)CH Chassis Mode Operationnd No Drive (option)Ld Lifting Disabled (option)Diagnostic Tr ouble Codes (DTC)Diagnostic Trouble Codes (DTC)These codes are generated by the system toindicate that a device or circuit malfunction hasbeen detected in the electrical system.The types of Diagnostic Trouble Codes that mayoccur are explained below.Type "HXXX" – Indicate a malfunction associatedwith devices that control hydraulic functions in theelectrical system. The "HXXX" faults are dividedinto short circuit battery negative, short circuit tobattery positive, open circuit and generic shorts.Examples of these devices are solenoid controlledhydraulic valves and motor controller.Type "PXXX" – Indicate a malfunction associatedwith power type devices in the electrical system.The "PXXX" faults are divided into short circuit tobattery negative, short circuit to battery positive,open circuit and generic shorts. Examples of thesedevices are horns, sensor power and alarms.Type "UXXX" – Indicate a malfunction associatedwith user interface devices in the electrical system.The "UXXX" faults are divided into short circuit tobattery negative, short circuit to battery positive,open circuit and generic shorts. Examples of thesedevices are GCON up and down switches andPCON drive joystick.Type "FXXX" – Indicate a malfunction associatedwith machine feedback devices in the electricalsystem. The "FXXX" faults are divided into shortcircuit to battery negative, short circuit to batterypositive, open circuit and generic shorts. Examplesof these devices are limit switches, height sensorsand pressure transducers.Type "CXXX" – Indicate a malfunction associatedwith controls devices in the electrical system.Examples of these devices are platform controlsand ground controls ECM.
PreviousNext |