Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Specifications
- Hydraulic Oil Specifications
- Hydraulic Component Specifications
- Hydraulic Hose and Fitting Torque Specifications
- Torque Procedure
- Repair Procedures
- Platform Controls
- Circuit Board
- Joystick
- Platfrom Controls Alarm
- Platform Components
- Platform Extension Deck
- Scissor Components
- Scissor Assembly, GS-2669 DC
- Scissor Assembly, GS-3369 DC
- Scissor Assembly, GS-4069 DC
- Wear Pads
- Lift Cylinders
- November
- Ground Controls
- Software Revision Level
- Machine Setup
- Auxiliary Platform Lowering
- Level Sensor - Models with Outriggers
- Service Override Mode
- Hydraulic Pump
- How to Calibrate the Hydraulic Pump
- Manifolds
- a Function Manifold Components
- Valve Adjustments - Function Manifold
- How to Adjust the Oscillate Relief Valve
- How to Adjust the Steer Relief Valve
- How to Adjust the Platform Up Relief Valve - Models without Platform Overload
- Outrigger Manifold Components
- Valve Coils
- Hydraulic Tank
- Steer Cylinder
- Oscillate Cylinder
- Steer Angle Sensor
- Non-steer Axle Components
- Drive Hub
- Outrigger Components
- Outrigger Calibration
- Platform Overload Components
- Platform Overload Recovery
- Fault Codes
- GCON I/O Map
- Operation Indicator Codes (OIC)
- Troubleshooting "HXXX" and "PXXX" Faults
- Fault Inspection Procedure
- Type "HXXX" Faults
- Type "PXXX" Faults
- Type "UXXX" Faults
- Type "FXXX" Faults
- Type "CXXX" Faults
- Section 5 Schematics
- Electrical Schematic Abbreviations and Wire Color Legends
- Hydraulic Component Legend
- Electrical Symbols Legend
- Hydraulic Symbols Legend
- Limit Switch Legend
- Fuse, Ground and Platform Control Boxes
- Fuse Box Layout, All Models
- Ground Control Box Layout, All Models
- Platform Control Box Layout, Models with 2 Speed Lift
- Control Box Layout, Models with Proportional Lift
- Electrical Schematics - ANSI / CSA
- Electrical Schematic, GS-2669 DC and GS-3369 DC with 2 Speed Lift, (ANSI CSA) (to serial number GS6915-6388)
- Electrical Schematic, GS-2669 DC and GS-3369 DC with Proportional Lift, (ANSI CSA) (from serial number GS6915-6389 to GS6915-7719)
- Electrical Schematic, GS-2669 DC and GS-3369 DC with Proportional Lift, (ANSI CSA) (from serial number GS6915-7720)
- Electrical Schematic, GS-4069 DC with 2 Speed Lift, (ANSI / CSA) (to serial number GS6915-6388)
- Electrical Schematic, GS-4069 DC with Proportional Lift, (ANSI / CSA) (from serial number GS6915-7720)
- Electrical Schematics - AS / CE
- Electrical Schematic, GS-2669 DC and GS-3369 DC with 2 Speed Lift, (AS / CE to serial number GS6915-6388)
- Electrical Schematic, GS-2669 DC and GS-3369 DC with Proportional Lift, (AS CE) (from serial number GS6915-6389 to GS6915-7719)
- Electrical Schematic, GS-2669 DC and GS-3369 DC with Proportional Lift, (AS CE) (from serial number GS6915-7720)
- Electrical Schematic, GS-4069 DC with 2 Speed Lift, (AS / CE) (to serial number GS6915-6388)
- Electrical Schematic, GS-4069 DC with Proportional Lift, (AS / CE) (from serial number GS6915-6389 to GS6915-7719)
- Electrical Schematic, GS-4069 DC with Proportional Lift, (AS / CE) (from serial number GS6915-7720)
- Hydraulic Schematics
- Hydraulic Schematic, GS-2669 DC and GS-3369 DC with 2 Speed Lift (to serial number GS6915-6388)
- Hydraulic Schematic, GS-2669 DC and GS-3369 DC with Proportional Lift (from serial number GS6915-6389)
- Hydraulic Schematic, GS-4069 DC with 2 Speed Lift (to serial number GS6915-6388)
- Hydraulic Schematic, GS-4069 DC with Proportional Lift (from serial number GS6915-6389)
|
Service and Repair Manual November 2016Ground Controls34 GS-2669 DC • GS-3369 DC • GS-4069 DC Part No. 1272220GT4-2 M ac hine Setup4-2Machine SetupHow to Setup the Machine fromGround ControlsThe ground controls can be used to setup themachine parameters from the ground. Featuresthat can be adjusted from the ground controlsinclude machine Model, Options and Speed setup.This menu can only be entered from groundcontrols with the key switch in the ground controlsposition.Tip-over hazard. Do not adjustfunction speeds higher thanspecified in this procedure.Setting the function speedsgreater than specifications couldcause the machine to tip overresulting in death or seriousinjury.Tip-over hazard. This proceduremust only be performed by atrained service professional.Attempting this procedurewithout the necessary skillscould result in death or seriousinjury.Note: Select a test area that is firm, level and freeof obstructions.1 Turn the key switch to the ground controlsposition and pull out the red Emergency Stopbutton to the on position at the platformcontrols.2 Press and hold the ground control scroll upand scroll down buttons.Ground Control Menu Buttons1 scroll down button2 enter button3 scroll up button4 escape button5 LCD display3 Pull out the red Emergency Stop button to theon position at the ground controls.Result: The ground controls LCD display willshow the following:4 Use the ground control menu buttons to selectmachine Model, Options and Speed Setupparameters. Follow the menu structureindicated on the ground control LCD display.