WARNING• Make sure doorway is in view and clear of obstaclesand people to avoid injury or damage to property.• DO NOT operate this unit from wall console beforeLIMITS and FORCE are set. Severe damage to theopener can occur.• The bullet MUST be engaged to carriage BEFOREsetting limits. See Installation Poster (if provided) orrefer to pages 11 and 19.NOTE: If bullet has NOT been engaged tothe carriage, do so now.©2010 The Genie Company 12/20106PROGRAMSET—+SETTING & TESTING LIMITS AND FORCEThe OPEN (UP) and CLOSE (DOWN) Door Limit positions are controlled by makingadjustments using the panel located on the bottom of the powerhead. Begin withStep 1 and continue through Step 10. Door Force is set during the final Open/Closecycle of these steps. The powerhead will automatically set door speed at slow if thedistance between limits is less than 6 feet. Once Limits and Force are set DO NOT usethe or buttons to open or close door.A) CLOSE DOOR TRAVEL LIMITNOTE: You can start and stop doormovement using either buttons untildoor is in correct open or closed position.Watch door movePROGRAMMING LIMITS & FORCE(Continuing from Installation Poster if provided)1OGRAMSET—+5PROGRAMSET—+PRESS and HOLDSEE BOTHBlue LEDscome ONSEE roundBlue LEDcome ONSEE round BlueLED flashingRELEASE1 2 34 NOTE: If one or both LEDs come ON REDat this time, Limits programming menuwas not entered properly. You must exitprogramming and restart.To exit the programming function wait 30seconds for the programming to time out.PRESS and RELEASEPlease note that there is a 30 second timeoutbetween each programming step.A programming timeout during these steps hasoccured when two RED flashing LEDs appear.In the event of a timeout please restart at Step 1.NOTICEIFDOORBECOMESOBSTRUCTEDIPULLDOWNONHANDLEPROGRAMSET—PRESS andRELEASESEE long BlueLED come ONIf RED LED comes ON - STOP andexit programming.PRESS and HOLD until door is FULLY CLOSED then RELEASE