Genie Monochrome Series-GigE Vision Camera Operational Reference • 49Reset Mode• Exposure starts immediately after a valid trigger. There is no jitter on the start of exposure.• Exposure time is programmable or controlled by the trigger pulse width.• Minimum exposure is 100 μs – maximum is 4 seconds, with control steps of 1μs.• Sensor readout must complete before the next exposure can start. That is, exposure and readout are sequential.Therefore, the maximum frame rate is lower than for Synchronous mode.• Any external trigger received before the previous exposure/read out sequence is complete is ignored. Anapplication can elect to receive messages about ignored triggers. See "Events" on page 65.Reset Mode Timing example for Genie M640Synchronization Mode via Sapera LT or GigE Vision CompliantApplicationsSaperaGenie Sapera parameters for Synchronization Mode:ExposureAlignment = {Synchronous = 0, Reset = 1}In CamExpert, these parameters are available under the “Sensor” tab in the “Exposure Control”dialog box.See "Accessing Features with Sapera++ LT" on page 69.XML features for Synchronization Mode:SensorSynchronization = {Synchronous = 0, Reset = 1}