52 • Operational Reference Genie Monochrome Series-GigE Vision CameraInput Controls via Sapera LT or GigE Vision Compliant ApplicationsSaperaGenie Sapera parameters for Trigger Modes and General Inputs:TriggerDelayToIntegration = Delay in μs from trigger to exposureTriggerEnable = {FALSE, TRUE}TriggerSource = {Input 1 = 0, Input 2 = 1, Software = 2}TriggerSoftware = {FALSE, TRUE}FramesPerTrigger = Frame count 1 to 64kPolarityInput_x = {Active High = 0, Active Low = 1}DebounceInput_x = debouncing period in μs (from 1 to 255 μs)See "Accessing Features with Sapera++ LT" on page 69.XML features for Trigger Modes and General Inputs:TriggerMode = {Off = 0, On = 1}TriggerSelector = (not used)TriggerSoftware = Generates a software trigger to start the acquisition in software trigger modeTriggerSource = {Line2 = 1, Software = 2}TriggerActivation = {LevelLow = 0, LevelHigh = 1}TriggerDelayAbs = Absolute delay to apply in us after reception of the trigger signal beforestarting exposureInputLineSelector = Index to general input {input1=0, input2=1}InputLinePolarity = {Active High = 0, Active Low = 1}InputLineDebouncingPeriod = debounce period in μs (from 1 to 255 μs)InputLineValue = Read input line state {low=0, high=1}