54 • Operational Reference Genie Nano-CL Series™Counter and Timer Control Feature DescriptionThe following table and block diagram, describes these parameters along with their view attributeand minimum camera firmware version required. Additionally the Device Version column willindicate which feature is a member of the DALSA Features Naming Convention (indicated byDFNC), versus the GenICam Standard Features Naming Convention (SFNC tag is not shown).The Device Version number represents the camera software functional group, not a firmwarerevision number. As Nano-CL capabilities evolve the device version tag will increase, thereforeidentifying the supported function package. New features for a major device version release will beindicated by green text for easy identification.Display Name Feature & Values Description DeviceVersion& ViewCounter Selector counterSelector Selects the counter to configure. 1.00ExpertDFNCCounter 1 Counter1 Select counter 1Counter mode counterMode Selects the counter mode. The selected Counter iseither Active or Disabled. When Disabled, the Countercan be configured.1.00ExpertDFNCOff Off The selected Counter is DisabledActive Active The selected Counter is EnabledCounter Status counterStatus Returns the current state of the counter. 1.00ExpertDFNCCounter Idle CounterIdle The counter is idle.The counterStartSource feature is set to off.Counter Trigger Wait CounterTriggerWait The counter is waiting for a start trigger.Counter Active CounterActive The counter is counting for the specified duration.Counter Completed CounterCompleted The counter reached the CounterDuration count.Counter Overflow CounterOverflow The counter reached its maximum possible count.Counter Start Source counterStartSource Select the counter start source. Counter incrementsfrom 0 to the value of the counterDuration feature.1.00ExpertDFNCOff Off Counter is stopped.Exposure Start ExposureStart Counter starts on the reception of the Exposure StarteventExposure End ExposureEnd Counter starts on the reception of the Exposure Endevent.Readout Start ReadoutStart Counter starts on the reception of the Readout Startevent.Readout End ReadoutEnd Counter starts on the reception of the Readout Endevent.Frame Start FrameStart Counter starts on the reception of the Frame Startevent.Valid Frame Trigger ValidFrameTrigger Counter starts on the reception of the Valid FrameTrigger.Rejected Frame Trigger InvalidFrameTrigger Counter starts on the reception of the Invalid FrameTrigger.CC1 CC1 Counter starts on the specified transitions on CC1.Timer 1 End Timer1End Counter starts on the reception of the Timer 1 Endevent.Counter 1 End Counter1End Counter starts on the reception of the Counter 1 Endevent.Counter Start LineActivationcounterStartLineActivation Selects the activation mode of the input line triggerwhich starts the counter. This is only applicable whenthe counterStartSource feature selects a physicalLine.1.00ExpertDFNC