June 2017 Service and Repair ManualPlatform ComponentsPart No. 1268497 SX-180 332-6Platform Overload RecoveryMessage (software V2.0 and later)If the ground controls LCD screen displaysOVERLOAD RECOVERY, the emergency loweringsystem has been used while the platform wasoverloaded.How to Clear the PlatformOverload Recovery MessageNote: This message shall be cleared by a persontrained and qualified on the troubleshooting andrepair of this machine.Note: Use the following chart to identify thedescription of each LCD screen control button usedin this procedure.Plus Minus Previous Enter1 Turn the key switch to the off position.2 Press and hold the enter button on the groundcontrol panel while turning the key switch toground controls. Hold the enter button forapproximately 5 seconds.3 Press the buttons on the ground controls in thefollowing sequence:(plus)(minus)(minus)(plus).4 Press the enter or previous button on theLCD screen until CLEAR OVERLOADRECOVERY is displayed.5 Press the plus button or the minus button toselect YES. Then press the buttons in thefollowing sequence:(plus)(plus)(plus)(minus). and press theenter button to accept.Note: The passcode buttons(plus)(plus)(plus)(minus) must be entered in theproper sequence before the enter button ispressed.6 Press the enter or previous button on theLCD screen until EXIT is displayed.7 Press the plus button or minus button toselect YES and then press the enter button.8 Turn the key switch to the off position.