June 2017 Service and Repair ManualDisplay ModulePart No. 1268497 SX-180 83This table lists the various screens and menu options of the operating software. Some display menus arefor informational purpose only, while others can be used to change the machine operating parameters.Tip-over hazard. Calibration and parameter settings must be completed by a persontrained and qualified on the repair of this machine. Failure to properly calibrate or setparameters could cause the machine to tip over resulting in death or serious injury.Note: The key switch must be in the off position before entering the programming mode.Note: Use the following chart to identify the description of each LCD screen control button used in thisprocedure.Plus Minus Previous EnterActivation of the enter or previous buttons scrolls through the screens. To change parameter values orselect a setting, use the plus button (to increase or scroll forward) and the minus button (to decrease orscroll backwards). Then press the enter button to save the new value to memory. An audible beep willindicate a save to memory. Use the enter and previous buttons to scroll to the EXIT menu. Use the plusbutton to change to YES and use the enter button to exit.Screen or Menu Procedure Description Range or SelectionOperator Default Hourmeter (on power up)Engine speedEngine oil pressure PSI(English)Engine oil pressure kPa (metric)Engine temperature °F(Engiish)engine temp will notdisplay until temp is>100°FEngine temperature °C (metric) engine temp will notdisplay until temp is>38°CPrimary boom angle to gravityTurntable level sensor X°directionTurntable level sensor Y°directionPlatform level sensor degreeBattery volts