107Item Model 3U55S2SR2FAFunction - Cooling HeatingRating Capacity W 5500 6800Cooling Pdesign W 5500Heating Pdesign (-10°C) W 4700Rated Power Input (Indoor + Outdoor) W 1380 1550Rated Current Input (Indoor + Outdoor) A 6.4 7.1EER/COP W/W 4.0 4.4SEER/SCOP W/W 7.5 4.0Minimum Capacity W 2100 1700Minimum Power Input W 550 550Maximum Capacity W 7000 7600Maximum Power Input (Indoor + Outdoor) W 2500 2200Power Source - 1PH, 220-240V~, 50/60HzMax. Running Current (Indoor + Outdoor) A/A 10.8 9.5Power Facor (Under Rating Power Input) - 99% 99%Starting Current A 4Fuse Size (Recommended Size) A 25Outdoor UnitCompressorModel / Manufacture - SVB140FCAMC-L/ MELCOMOil Charge and Type - 500CC/ FW68SType - Twin Rotary (DC Inverter)Number - 1FanType × Number - Axial × 1Speed r/min High 700Motor Output/Input Power W 90/130Air-Flows (H/M/L) m³/h About 3000Heat ExchangerType / Diameter mm TP2M / 9.52Row - 1Face Area m² About 0.6Dimension(WxDxH)External mm 890/340/700Package mm 998/443/770Refrigerant Control Method - EEVDefrosting Method - Automatic By Reversible CycleCrankcase Heater Power W NoneNoise Level Sound Power Level dB(A) 64Sound Pressure Level dB(A) 51Weight Net/Shipping kg / kg 51/55