109Item Model 3U70S2SR2FAFunction - Cooling HeatingRating Capacity W 7000 7600Cooling Pdesign W 7000Heating Pdesign (-10°C) W 6000Rated Power Input (Indoor + Outdoor) W 1750 1800Rated Current Input (Indoor + Outdoor) A 8.3 8.3EER/COP W/W 4.0 4.2SEER/SCOP W/W 7.5 4.2Minimum Capacity W 2400 2900Minimum Power Input W 550 550Maximum Capacity W 7600 8500Maximum Power Input (Indoor + Outdoor) W 2700 2300Power Source - 1PH, 220-240V~, 50/60HzMax. Running Current (Indoor + Outdoor) A / A 11.9 9.7Power Facor (Under Rating Power Input) - 99% 99%Starting Current A 4Fuse Size (Recommended Size) A 25Outdoor UnitCompressorModel/Manufacture - SVB140FCAMC-L/ MELCOMOil Charge and Type - 500CC/ FW68SType - Twin Rotary (DC Inverter)Number - 1FanType × Number - Axial × 1Speed r/min High 700Motor Output/Input Power W 90/130Air-Flows (H/M/L) m³/h About 3000Heat ExchangerType/Diameter mm TP2M / 7.0Row - 2Face Area m² About 0.6Dimension(WxDxH)External mm 890/340/700Package mm 998/443/770Refrigerant Control Method - EEVDefrosting Method - Automatic by Reversible CycleCrankcase Heater Power W NoneNoise Level Sound Power Level dB(A) 66Sound Pressure Level dB(A) 53Weight Net/Shipping kg / kg 54/58