111Item Model 4U75S2SR2FAFunction - Cooling HeatingRating Capacity W 7500 8600Cooling Pdesign W 7500Heating Pdesign (-10°C) W 6300Rated Power Input (Indoor + Outdoor) W 2000 2150Rated Current Input (Indoor + Outdoor) A 9.1 9.5EER/COP W/W 3.8 4.0SEER/SCOP W/W 7.0 4.0Minimum Capacity W 2400 3100Minimum Power Input W 550 550Maximum Capacity W 8700 10000Maximum Power Input (Indoor + Outdoor) W 3400 3100Power Source - 1PH, 220-240V~, 50/60HzMax. Running Current (Indoor + Outdoor) A / A 14.6 13.5Power Facor (Under Rating Power Input) - 99% 99%Starting Current A 5Fuse Size (Recommended Size) A 25Outdoor UnitCompressorModel/Manufacture - TVB220FAEMC-L/MELCOMOil Charge and Type - 870CC/FW68SType - Twin Rotary (DC Inverter)Number - 1FanType × Number - Axial × 1Speed r/min High 770Motor Output/Input Power W 90/130Air-Flows (H/M/L) m³/h About 4000Heat ExchangerType/Diameter mm TP2M / 7.0Row - 2Face Area m² About 0.6Dimension(WxDxH)External mm 890/340/700Package mm 998/443/770Refrigerant Control Method - PMVSDefrosting Method - Automatic by Reversible CycleCrankcase Heater Power W NoneNoise Level Sound Power Level dB(A) 68Sound Pressure Level dB(A) 55Weight Net/Shipping kg / kg 61/65