4 - Sprayer Setup79Electrical ConnectionsPower SupplyPower requirement is 12 V DC. Always note the polarity!For proper function of the electric equipment for the sprayer, the tractormust have the following sizes of electric wires and fuses installed.The delivered power connectors follow the standard of most modern tractors. If you have a tractor with another powerconnector, it is necessary to disassemble the connector and fit it to the actual sprayer connector. Contact your HARDI dealer.The delivered connectors may vary on the sprayer, depending on its equipment and scope of supply.Road Safety KitIf rear lights are installed, connect the plug for rear lights to the tractor’s7-pin socket and check the function of rear lights, stop lights, side lightsand direction indicators on both sides before driving.The wiring is in accordance with ISO 1724. See the chapter “TechnicalSpecifications” in this Instruction Book. ATTENTION! Turn OFF all work lights when driving on public roads!Spray box connector, 1-pin plugThe unit requires:Wire 2.5 mm2 . Fuse 10 amps.Hydraulic control unit requires:Wire 4.0 mm2 . Fuse 16 amps.Tractor must follow ISO 4165.JobCom connector, 3-pin plugThe unit requires:Wire 6.0 mm2 . Fuse 25 amps.Tractor must follow DIN 9680.Traffic light connector, 7-pin plugThe unit requires:Wire 6x 1.5 mm2 + 1x 2.5 mm 2.The cable is custom made and must notbe changed to another type.Tractor must follow ISO 1724.ISOBUS connector, 9-pin plugThe unit requires:Wire 2x 10 mm2 + 2x 2.5 mm2 + 2x (2x 0.5 mm 2)The cable is custom made and must not bechanged to another type.Tractor must follow ISO 11783-2.Cabin connector for grip control and Setbox:HARDI item no. 26031500Power and data connector, 13-pin plugUsed for controller model HC 6500.If needed, buy one of these tractor kits tocomplete the setup:HARDI item no. 26049400 (incl. NORAC system)HARDI item no. 26013900 (excl. NORAC system)Tractor must follow ISO 11446.