3 - Description22CycloneFilterWith the CycloneFilter, any impurities in the spray liquid will by-pass thefilter and be re-circulated back to the tank via the return flow.Function diagram1. Filter lid2. From pump3. To boom4. Return to tank5. Return valveThe valve (5) has three positions marked with small dots on the lever:A. This position marked with 1 dot: There is no return flow. Position isused when rinsing the boom, if there is spray liquid in the maintank. Also used when high spraying volume is required.B. This position marked with 2 dots: Normal spraying position. Withreturn flow to prevent filter is going to be clogged when spraying.This position is used when rinsing the boom, if the main tank is empty.C. This position marked with 3 dots: Flushing position which is used if filter is clogged. Lift and hold the lever to use thisposition, which largely increases return flow and flushes the filter. The pressure SmartValve must be set to “Spraying”.μ ATTENTION! Use of position C is no guarantee for a clean filter. Always regularly do a visual inspection and cleaningof the filter. If necessary, see “10 Hours Service - CycloneFilter” on page 79.€ DANGER! Never open the Cyclone filter unless the suction valveis closed and the pressure SmartValve is turned to “Main tank”.Otherwise, spraying liquid may hit you, when opening the filter,and thereby draining the main tank!