5 - Operation74Pressure Draining (optional)It is possible to drain to an external tank. This is done the following way:1. Connect a hose from an external tank to the pressure quickcoupler on the sprayer.2. Turn the Pressure SmartValve towards .3. Turn the suction valve towards .4. Engage the PTO to start the pump.5. When the tank is drained, then turn off the PTO again.6. Disconnect the hose and put back the quick coupler lid.€ DANGER! Before turning Pressure SmartValve to , it is very important to ensure that the quick coupler lid iscorrectly and completely mounted to the filling stud in its locked position. Failure to do so causes a risk ofcontamination and injury from the quick coupler lid being “shot” off when pressurized! If it is not possible to mountthe lid completely, lubricate the rubber seal and the grip hooks.Outside Cleaning - Use of External Cleaning Device (optional)Use the External Cleaning Device to wash everything on the outside of the sprayer.1. Unroll the hose from the reel.2. Engage pump speed to approximately 250 rpm or 560 rpm,depending on pump model.3. Turn suction SmartValve towards and pressure SmartValvetowards or not used function.4. Turn agitation valve towards and clean the sprayer.5. After cleaning, close the agitation valve again.6. Roll the hose to the reel again.€ DANGER! Before turning Pressure SmartValve to , it is veryimportant to ensure that the quick coupler lid is correctly and completely mounted to the filling stud in its lockedposition. Failure to do so causes a risk of contamination and injury from quick coupler lid being “shot” off whenpressurized! If it is not possible to mount lid completely, lubricate the rubber seal and the grip hooks.μ ATTENTION! If the safety valve is activated, then lower the PTO speed to minimize the amount of rinsing water beinglost into the main tank.μ ATTENTION! If the sprayer is cleaned with a high pressure washer, lubrication of the entire machine is recommended.• Spray Technique - see separate book.• Optional Extras - see separate books.