6 - Maintenance7910 Hours Service - CycloneFilterServicing the filter1. Turn the pressure valve towards the unused function or to tankcleaning nozzles.2. Unscrew the filter lid (A).3. Lift lid and filter (B) from the housing.4. Turn the two locks (C) outwards to unlock the filter from the lid.5. Separate filter from the integrated filter guide in the lid and cleanthe filter.To reassemble1. Grease the two O-rings on the lid/filter guide. Due to small spaceat lid, use for example a brush to apply the grease.2. Mount the filter onto the recess (which may not be greased) in thelid/filter guide.3. Turn the two locks (C) inwards to lock the filter to the lid.4. Place the filter/filter lid into the housing and screw the lid, until it hits the stop.± WARNING! Always wear protective clothing and gloves, before servicing the filter!€ DANGER! The pressure valve must always be turned to the unused function or to tank cleaning nozzles, beforeopening the CycloneFilter! If not, the spraying liquid can hit you, when opening the filter, and the main tank contentwill drain away!10 Hours Service - In-Line Filter (optional)If the boom is equipped with In-Line Filters, unscrew the filter bowl toinspect and clean the filter. When reassembling, the O-ring should begreased.Alternative filter meshes are available. See section on Technicalspecifications - Filters and nozzles.± WARNING! Be careful not to splash out liquid, when unscrewingthe filter bowl.± WARNING! Always wear protective clothing and gloves, beforeservicing the filter!10 Hours Service - Nozzle FiltersThe filters are located inside the nozzles. Check and clean.