IBM 7133 Series Service Manual
SRN FRU List Problem| 49100| None| Description: A RAID array is in the Exposed state because a disk| drive is not available to the array.| Action: Go to the SRN table in the SSA Adapters: User’s Guide| and Maintenance Information manual, and follow the instructions| for this SRN.| 49500| None| Description: No hot spare disk drives are available for a RAID| array that is configured for hot spare disk drives.| Action: Go to the SRN table in the SSA Adapters: User’s Guide| and Maintenance Information manual, and follow the instructions| for this SRN.| 49700| None| Description: The parity for the RAID array is not complete.| Action: Go to the SRN table in the SSA Adapters: User’s Guide| and Maintenance Information manual, and follow the instructions| for this SRN.50100 None Description: An attempt was made to log an error against a pdiskthat is not available to the using system.Action: This problem has occurred for one of the followingreasons: A user has deleted a pdisk from the system configuration. Insuch an instance, the hdisk that is related to the pdiskcontinues to operate normally. If the disk drive module triesto log an error, however, this SRN (50100) is produced. Givethe cfgmgr command to return the pdisk to the systemconfiguration. A disk drive module has tried to log an error during systemconfiguration. To find the failing disk drive module, rundiagnostics to the disk drive modules that are connected tothis SSA adapter.60200 None Description: The 7133 cannot be turned on.Action: Go to “MAP 2020: 7133 – Power” on page 2-2020-1.60210 Disk-drive module (100%)(“Disk Drive Modules” on page 3-17).Description: A disk drive module has its Check light on.Action: Exchange the FRU for a new FRU.60220 Fan-and-power-supply assembly(100%)(“Fan-and-Power-Supply Assemblies” onpage 3-32).Description: A fan-and-power-supply assembly has its Check lighton.Action: Exchange the FRU for a new FRU.60230 None Description: The 7133 has an unexpected Check light on.Action: Go to “MAP 2020: 7133 – Power” on page 2-2020-1.60240 None Description: A configuration problem has occurred.Action: A disk drive module cannot be configured, for someunknown reason. Go to “MAP 2010: 7133 – START” onpage 2-2010-1. If no problem is found, go to “Software andMicrocode Errors” on page 2-8.7XXXX None Description: An SSA disk drive is missing from the expectedconfiguration of the SSA loop.Action: The missing disk drive is not associated with a 7133. Goto the service information for another device that is in the sameSSA loop.Note: In this SRN, an X represents a digit 0 through F.D0000 Disk drive module (100%)(“Disk Drive Modules” on page 3-17).Description: The using system cannot configure the disk drivemodule.Action: This is probably a software problem. Try again toconfigure the disk drive module.If the problem remains, go to “Software and Microcode Errors” onpage 2-8 before exchanging the FRU.D0100 Disk drive module (100%)(“Disk Drive Modules” on page 3-17).Description: Unable to clear a disk drive module reservation.Action: Exchange the FRU for a new FRU.Chapter 2. Problem Determination Procedures 2-7 |
Related manuals for IBM 7133 Series
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine