256 IBM Power Systems 775 for AIX and Linux HPC SolutionFSP Backup ip=40.6.5.1 MTMS=9125-F2C*02C6986FSP Backup ip=40.6.7.1 MTMS=9125-F2C*02C69D6FSP Primary ip=40.6.10.2 MTMS=9125-F2C*02C6A46 FR006-CG12-SN005-DR14.2.6 Verify that a multicast tree is present and correctA missing or incorrect multicast tree causes communication issues on the service network,such as nodes that fail to communicate with or ping each other. Verify the presence andintegrity of the multicast tree, as shown in Example 4-20.Example 4-20 Verifying the multicast tree# cat /var/opt/isnm/cnm/log/mctree.out********************************************************Multicast tree starts with root********************************************************Root: FR006-CG07-SN004-DR0-HB31: FR006-CG07-SN004-DR0-HB3-1-->FR006-CG07-SN004-DR0-HB0-12: FR006-CG07-SN004-DR0-HB0-2-->FR006-CG07-SN004-DR0-HB5-13: FR006-CG07-SN004-DR0-HB5-2-->FR006-CG07-SN004-DR0-HB2-43: FR006-CG07-SN004-DR0-HB5-3-->FR006-CG07-SN004-DR0-HB4-62: FR006-CG07-SN004-DR0-HB0-3-->FR006-CG07-SN004-DR0-HB1-33: FR006-CG07-SN004-DR0-HB1-2-->FR006-CG07-SN004-DR0-HB6-43: FR006-CG07-SN004-DR0-HB1-7-->FR006-CG07-SN004-DR0-HB7-72: FR006-CG07-SN004-DR0-HB0-42-->FR006-CG11-SN005-DR0-HB0-433: FR006-CG11-SN005-DR0-HB0-1-->FR006-CG11-SN005-DR0-HB3-13: FR006-CG11-SN005-DR0-HB0-2-->FR006-CG11-SN005-DR0-HB5-13: FR006-CG11-SN005-DR0-HB0-3-->FR006-CG11-SN005-DR0-HB1-33: FR006-CG11-SN005-DR0-HB0-4-->FR006-CG11-SN005-DR0-HB4-13: FR006-CG11-SN005-DR0-HB0-5-->FR006-CG11-SN005-DR0-HB2-23: FR006-CG11-SN005-DR0-HB0-6-->FR006-CG11-SN005-DR0-HB7-33: FR006-CG11-SN005-DR0-HB0-7-->FR006-CG11-SN005-DR0-HB6-73: FR006-CG11-SN005-DR0-HB0-8-->FR006-CG12-SN005-DR1-HB0-8If the multicast tree is incorrect (for example, if it does not include all the expected cages),remove the file, re-ipl the CECs, and recycle CNM.Important: The output of lsnwcomponents indicates that the cluster contains a single78AC-100 frame FR006 with three supernodes: SN004 with 4x9125-F2C servers in cages7-10, SN005 with 4x9125-F2C servers in cages 11-14, and SN051 with 4x9125-F2Cservers in cages 3 - 6.