Troubleshooting tablesUse the troubleshooting tables to find solutions to problems that have identifiablesymptoms. See the Problem Determination and Service Guide on the IBM System xDocumentation CD for more detailed troubleshooting information. If you cannot finda problem in these tables, run the diagnostic programs (see “Running the diagnosticprograms” in the Problem Determination and Service Guide).If you have just added new software or a new optional device and the server is notworking, complete the following steps before you use the troubleshooting tables:1. Check the system-error LED on the operator information panel (see Chapter 3,“Server controls, LEDs, and power,” on page 21).2. Remove the software or device that you just added.3. Run the diagnostic tests to determine whether the server is running correctly.4. Reinstall the new software or new device.CD or DVD drive problemsv Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See the parts listing in the Problem Determination and Service Guide to determine which components arecustomer replaceable units (CRU) and which components are field replaceable units (FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.Symptom ActionThe CD or DVD drive is notrecognized. 1. Make sure that:v The IDE channel to which the CD or DVD drive is attached (primary) isenabled in the Configuration/Setup Utility program.v All cables and jumpers are installed correctly.v The correct device driver is installed for the CD or DVD drive.2. Run the CD, CD-RW, or DVD drive diagnostic programs.3. Reseat the following components:a. CD or DVD driveb. CD or DVD interface board cable4. Replace the following components one at a time, in the order shown, restartingthe server each time:a. CD or DVD driveb. CD or DVD drive interface board cablec. CD or DVD interface boardd. (Trained service technician only) System boardA CD or DVD is not workingcorrectly. 1. Clean the CD or DVD.2. Run the CD or DVD drive diagnostic programs.3. Reseat the CD or DVD drive.4. Replace the CD or DVD drive.The CD or DVD drive tray is notworking. 1. Make sure that the server is turned on.2. Insert the end of a straightened paper clip into the manual tray-releaseopening.3. Reseat the CD or DVD drive.4. Replace the CD or DVD drive.Chapter 5. Solving problems 37