218-906-000 Brocade:InternalLoopbackTest FailedExplanation: A failure was detected during the Loopback test.Severity: ErrorServiceable: YesRecoverable: NoAutomatically notify Support: NoUser response: Complete the following steps:1. Rerun the test.2. Verify whether the firmware is at proper level.3. Rerun the test.4. If the problem remains, contact your IBM technical-support representative.Related Links:v IBM Support Websitev Latest level of DSAv Latest level of BMC/IMMDSA checkpoint panel test resultsThe following messages can result when you run the checkpoint panel test.180-000-000 Check-point Panel Test PassedExplanation: Check-point Panel Test Passed.Severity: EventServiceable: NoRecoverable: NoAutomatically notify Support: NoRelated Links:v IBM Support Websitev Latest level of DSAv Latest level of BMC/IMM180-801-000 Check-point Panel Test AbortedExplanation: Check-point Panel Test Aborted. BMC is unable to verify that the operator information panel cable isconnected.Severity: WarningServiceable: YesRecoverable: NoAutomatically notify Support: NoUser response: Complete the following steps:1. Inspect and reseat operator information panel cable at both ends.2. Verify that the Baseboard Management Controller (BMC) is working.3. Run the test again.4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for thenext corrective action.218-906-000 • 180-801-000710 IBM System x3550 M4 Type 7914: Installation and Service Guide