IDS 816 700-283-02I Issued September 200919LOCATION 0 Defaulting of the Panel or Master User CodeValue Action0 Will reset all locations to the factory default values.(Master User Code 1234) and all keypad IDs will be defaulted.1Will default the master user code to 1234- or 123456 if 6 digits are being used.Master user code properties will also be defaulted.2 Defaults ALL users3 Defaults ALL keypads4Remove Missing DevicesA missing device (keypads, for example), will have its address freed up, makingits address available for a new device when it is enrolled. This MUST be donewhen replacing a faulty device – see “Enrolling Keypads and other Devices”,page 13.7.6.1 Zone OptionsLOCATIONS 1 - 16 Individual Zone SetupSub-location 1 Zone typeThe first sub-locations of program locations 1 - 16 are used to define the zone characteristics of each ofthe sixteen zones. There are 13 zone types. Table 3 provides a location/zone cross-reference togetherwith the default zone characteristics.Table 3 : Location / Zone DefaultsZone Location Sub-location 1 Default Zone Type1 1 1 Entry / Exit2 2 2 Follower3 3 4 Audible Instant4 4 4 Audible Instant5 5 4 Audible Instant6 6 4 Audible Instant7 7 4 Audible Instant8 8 4 Audible Instant9 9 0 Disabled10 10 0 Disabled11 11 0 Disabled12 12 0 Disabled13 13 0 Disabled14 14 0 Disabled15 15 0 Disabled16 16 0 DisabledTable 4 provides a complete list of the different zone types together with a description of theircharacteristics.