IDS 816 700-283-02I Issued September 2009 20Table 4 : Programmable Zone TypesValue Zone Type0DISABLEDA Zone violation of a disabled zone is ignored by the control panel and will not be indicated onthe keypad.1PRIMARY ENTRY / EXIT ZONEViolations of an Entry/Exit zone are ignored during the exit delay period of the armingprocedure. Violating an Entry/Exit zone when armed will initiate the entry delay. If valid UserCode is not entered before the entry delay period expires, an alarm condition will be registered.Failure to exit through an Entry/Exit zone after arming will cause the panel to Stay Arm.This zone may also function as an Entry/Exit zone that is COMMON to two partitions. In such acase, should a user violate this zone and then disarm his partition, the OTHER partition will re-arm after the entry delay.8 SECONDARY ENTRY / EXIT ZONEThe secondary entry delay will be activated if this zone is violated when the panel is armed.2FOLLOWER ZONEA violation of a Follower zone is ignored during the entry/exit delay period (this allows the userto enter/exit via the Follower zone). A Follower zone will behave as an instant zone if the panel isarmed and an Entry/Exit zone is not violated prior to violation of the follower zone.3PANIC / PRIORITY ZONERegardless of whether the panel is armed or not, a violation of a Priority zone will cause thecontrol panel to register a panic condition.This zone type CANNOT be bypassed.4INSTANT ZONEWhen the panel is armed the violation of an instant zone will cause the control panel to registeran alarm condition.5ARM/DISARM ZONEThe violation of an Arm/Disarm zone will cause the panel to toggle between (away) armed anddisarmed. It is typical to connect a momentary key-switch, or non-latching remote control unit tothis zone.9 RESERVED10FIRE ZONEViolation of a Fire zone will cause the siren to sound regardless of whether the panel is armed ornot. The siren will sound intermittently (one second on, one second off) For correct operation aprogrammable output programmed as a fire detector power output must be used to controlpower to the fire detector.There is a 10 second violation when unarmed and instant when armed.11TAMPER ZONEViolation of this zone will be reported to the base station regardless of whether the panel isarmed or disarmed. If the panel is armed, the siren will be activated.12 24 HOUR ALARM ZONEThis works the same as a panic zone – with the exception that it can be bypassed.13WARNING ZONEWhen the panel is armed, violation of a warning zone will cause the siren to beep. The violationis logged in the event log but it is not reported to the base station. Warning zones may beincluded and will be counted when used as part of the cross-zone matrix.14 PUSH TO ARM ZONEViolation of a push to arm zone during the exit delay will immediately arm the panel.15OUTDOOR INSTANT ZONEWhen the panel is armed violation of an outdoor instant zone will cause the panel to register analarm condition.