IDS 816 700-283-02I Issued September 200949NOTE:A master user code allows for the programming of other user codes in User Programming Mode.User Reporting Codes (for 4x 2 and Domestic Reporting)For all these locations, a two digit hexadecimal code must be programmed. To disable a reporting codea double zero (00) must be entered into the corresponding location. Note that if one of the above-mentioned reporting digits is inadvertently omitted or programmed as a zero, the code will not bereported. The exception to this rule is when using domestic reporting where only the first digit is used.Sub-location 3 Close Reporting CodeThis code is reported when the panel is AWAY ARMED.Sub-location 4 Stay Close Reporting CodeThis code is reported when the panel is STAY ARMED.Sub-location 5 Open Reporting CodeThis code is reported when the panel is disarmed.Sub-location 6 Siren Cancel Reporting CodeIf the siren is sounding and the siren is cancelled using a valid user code, a cancel code will be reported.Cancelling a silent alarm or silent panic will not cause the cancel siren code to be reported.14. Programmable Output OptionsLOCATIONS 388 – 394 Programmable Output Timing SetupLocations 388 to 394 allow the installer to setup the timing characteristics of each programmable outputindividually.Location Output No. Output Type388 1 Panel prog. output 1389 2 Panel prog. output 2390 3 Panel prog. output 3391 4 Panel prog. output 4392 5 Panel prog. output 5393 6 Zone expander prog. output 2394 7 Zone expander prog. output 1