IDS 816 700-283-02I Issued September 200937Table 10 : Standard Contact ID Reporting CodesDescription Codes Description CodesKeypad medical 1100 Cancel 1406Fire 1110 Open by download 1407Keypad Fire 1110 Open with key-switch 1409Panic 1120 Low battery 1302Panic zone 1120 Sounder/Relay trouble 1320Keypad panic 1120 Expansion module fail 1333Duress 1121 Zone/Sensor bypass 1570Burglary violation 1130 Zone/Sensor bypass restoral 3570Perimeter violation 1131 Burg. bypass 1573Interior violation 1132 Test report 160224 Hour (safe) violation 1133 Panic restore 3120Entry/Exit violation 1134 Zone restoral 3130Day/night violation 1135 Keypad tamper restore 3137Outdoor violation 1136 Zone restoral 3130Tamper violation 1137 Sensor tamper restore 3144Keypad tamper 1137 Expansion module tamper restore 3145Keypad lockout 1137 RF low battery restore 3384Near alarm violation 1138 Close by user 3401Tamper by zone 1144 Close by auto arm 3403Expansion module tamper 1145 Close by download 3407Exp. module low bat 1338 Close with key-switch 3409RF receiver jam detect 1344 Expansion module fail restore 3333Long range transmitter fault 1353 AC loss 3321Loss of supervision RF 1381 AC restoral 3333RF low battery 1384 Low battery restore 3302Open by user 1401 Sounder/Relay restore 3320NOTES ON DOMESTIC REPORTING:If Dual Reporting is enabled, Domestic reporting may either be reported to 2 telephone numbers or usingthe dual reporting option, report to a central station as well as to an individual mobile phone etc. Thisformat provides for a simple form of easily identifiable remote alarm which may be reported to an office,mobile phone etc.A series of tones is transmitted to the phone, which notifies the user that an alarm conditionhas occurred. If a 1 is programmed to a location, a single beep will be heard if that particular alarmcondition occurs. If a 2 is programmed to a location, 2 beeps will be heard etc.NOTE:If the system is armed using the quick arm key [1] the system will report a close by user 35.If the system is armed by means of a key switch or non-latching remote receiver connected toan arm/disarm zone the system will report a close by user 34.Enabling / Disabling Reporting GroupsLocations 118 to 120 are used to either enable or disable the reporting of groups of reporting codeswhen using Contact ID.