VQUICK REFERENCE GUIDENew2001■ Programmed scan operation25 pairs (50 channels) of scan edge memories, specify thescanning ranges, are used for programmed scan operation.The programmed scan scans between the frequencies inchannels “xxA” and “xxB” (xx=00 to 24). Therefore, beforeoperating the programmed scan, different frequencies mustbe programmed into “A” and “B” scan edge channels.D Programming scan edgesA start frequency must be programmed into a “xxA,” and anend frequency must be programmed into a “xxB” memorychannel.1. Setting frequencyIn the VFO mode, set a desired receive frequency andreceive mode.• When the “ ” icon is displayed, push [V/M] to select the VFOmode.2. Selecting a scan edge “A” channelHold down [S.MW](V/M) for 1 second, then rotate [DIAL] toselect one of the 25 scan edge “A” channels.• The “ ” icon and scan edge channel number blink.3. Writing a scan edge channelHold down [S.MW](V/M) for 1 second until 3 beeps sound.• The paired scan edge “B” channel is automatically selected if youcontinue to hold down [S.MW](V/M) after programming.• When programming is completed, return to the VFO mode.4. Setting frequencyIn the VFO mode, set a desired receive frequency.5. Selecting a scan edge “B” channelHold down [S.MW](V/M) for 1 second, then rotate [DIAL] toselect one of the 25 scan edge “B” channels.• The “ ” icon and the scan edge channel number blink.• When the scan edge “B” channel is already selected in step 3, (byholding down [S.MW](V/M) after programming), skip this step.6. Writing a scan edge channelHold down [S.MW](V/M) for 1 second until 3 beeps sound.• The next scan edge “A” channel is automatically selected if youcontinue to hold down [S.MW](V/M) after programming.• When programming is completed, return to the VFO mode.Quick reference guide