152.2 RATING PLATECertified as:Direct vent gas fireplaceCSA 2.22-2012ANSI Z21.50-2012LOCATION : Quebec, Qc, CanadaModels :RGP 25 Mistral, RGB 25 Sirocco, RGCG 25 Auster,RGV 25 Suroit, RGC 25 Pampero, RGR 25 Loo,RGCD 25 MoussonSERIAL NO. :GAS Supply pressure NormalBTU/hBurner orificesize ManifoldPressureMinimum Normal BurnerNatural 3.5” WC. 7” WC. 21,000 0.0905”(2.29mm) 3.5 WC.Natural 3.5” WC. 7” WC. 23,000 #42 3.5 WC.Natural 3.5” WC. 7” WC. 25,000 #41 3.5 W.C.LPG GAS 8”WC. 11” WC. 21,000 #54 10 W.C.LPG GAS 8”WC. 11” WC. 27,000 #53 10 W.C.LPG GAS 8”WC. 11” WC. 32,000 #1/16 10 W.C.ALTITUDE 0-610 M / 0-4500 FtMINIMUM CLEARANCES TO COMBUSTIBLE MATERIALBACK TOP SIDES BOTTOM0”/ 0 cm ** 17”/43.18cm ** 1”/ 2.54 cm ** 0”/ 0 cm **Mantle : ** From the opening : **See installation instructions for detailsVented gas Fireplace- Do not Use with Solid fuelElectrical requirement for optional fan (115 Volts, 60 Hz, 0.20 Amps) normal power consumption is 23 watts.For Use with glass door certified with this appliance only. This appliance must be properly connected to a ventingsystem in accordance with the manufacturer’s installation instructions. WARNING: Failure to position the part inaccordance with these diagrams or failure to use only parts specifically approved with this appliance may resultin property damage or personal injury. Keep burner and control compartment clean. See installation and operatinginstructions accompanying appliance. This appliance must be installed in accordance with local code, if any; ifnone, follow the current ANSI Z223.1, or CSA B149, Installation codes.CAUTION: Hot while in operation. Do not touch theappliance. Severe burns may result. Keep children,clothing and furniture away.Do not use with solid fuelFor use with glass door certified with this appliance onlyNot for use in Mobile Home