516.2 INSTALLATION EQUIPMENT REQUIRED FOR GAS LINESMake sure you have on hand the following items before installing the fireplace:• An external regulator. The installer must supply an external regulator for propane/LPG connection. Thepurpose of the regulator is to reduce incoming gas pressure (Table 6.4). If intake pressure is not adjustedproperly, the SmartCase®’ automatic valve could be damaged (see section 6.4).• A pipeline network (check local codes).• CSA approved gas lines sealant.• A manual valve has to be placed inside the lower compartment of the appliance (before SmartCase®) (figure6.2).• A pressure gauge connection.• A sediment trap (recommended) (figure 6.2).• An approved flexible gas line equipped with a connector (figure 6.2).WARNINGConnection must be performed by a certified installer.CAUTIONA manual shut-off valve must be installed before the SmartCase®. It must be easy to access(see figure 6.2).CAUTION:Never connect the gas line directly to the fireplace operating on propane (LPG) or natural gas (NG). Thissystem requires an external regulator (not supplied). Install the external regulator directly on the cylinder andadjust the pressure according to the table featured in section 6.4.WARNING:Connection of gas lines to the appliance must be performed by a certified installer. Observe all localinstallation codes.Figure 6.2