143US. 33E.dOH functionThis parameter can be used to select what type of current check is performed.Additionally it determines whether or not the brake on/off message is displayed. In theevent there is a problem getting a consistently positive phase check, it is possible toswitch to only a magnetizing current check. The possibilities are defi ned below.Value Function0 Off (for temporary adjustment only)1 Magnetization current check with brake on/off display2 Magnetization current check without brake on/off display3 (default) Phase current check with brake on/off display4 Phase current check without brake on/off displayUS. 25Phase currentcheckAdvanced ParametersUS. 29HSP5Watchdog timeUS. 28Analog inputnoise clampThis parameter can be used to suppress noise on the analog speed pattern. Whenadjusted to a value greater than zero it will act as a hysteresis level above which theanalog signal must rise before the drive begins to act on it. With a negative valuethe drive applies the same hysteresis to constant speed, i.e. at high speed.Unit: 0.1 % = 10mVValue range: 0.1...10.0 %Default setting: 0.1 %Recommended adjustment: 0.1%This parameter adjusts the serial watchdog on the HSP5 com. link betweenthe operator and the drive. If the operator is removed from the drive, the serialcommunication stops. If it does not restart before this timer expires the drive willtrigger a fault and stop the operation of the motor.A setting of 0 or OFF turns off the watchdog allowing operation of the drivewith the operator removed. Note this mode of operation is recommended onlyfor trouble shooting purposes.Unit: 0.01 secValue range: 0.01...10.00 secDefault setting: 1.00 secRecommended adjustment: 1.00 secThis parameter can be used to activate the temperature sensor input (T1 and T2)on the drive. With this input activated, if the resistance between T1 and T2 becomesgreater than 1650 ohms, the drive will trigger an E.dOH error indicating that thetemperature sensor is too hot. Note: there is a 60 second time delay between whenthe sensor triggers and when the drive triggers the fault.Value range: off...onDefault setting: off