147Input/Output Configuration9.2 Digital OutputParameters The digital output parameters can be used to confi gure the digitaloutputs for operation. Normally these parameters only need to beadjusted by the Elevator control builder.do.42OutputInversionCan be used to invert the function of the output. As an example, normally on becomesnormally off. Each output is assigned a value. To invert the output set this parameterto the corresponding value. To invert more than one output set this parameter tothe sum of the values. Example X2A.18 = 1 and X2A.19 = 2, to invert both set thisparameter equal to 3.Value Output Terminal1 X2A.18 +24VDC solid state output2 X2A.19 +24VDC solid state output4 X2A.24..26 form C relay output8 X2A.27..29 form C relay outputUnit: -Value Range: 0...15Default Setting: 0This parameter determines the function of the +24VDC solid state drive outputX2A.18. The function can be selected from the table on the following page.Default Setting: ASdThis parameter determines the function of the +24VDC solid state drive outputX2A.19. The function can be selected from the table on the following page.Default Setting: FLtThis parameter determines the function of the relay output X2A.24..26. The functioncan be selected from the table on the following page.Default Setting: rdyThis parameter determines the function of the relay output X2A.27..29. The functioncan be selected from the table on the following page.Default Setting: drodo.80OutputX2A.18do.81OutputX2A.19do.82OutputX2A.24..26do.83OutputX2A.27..29