84Digital speed setting uses preset digital values in the drive ascommand speeds. The drive creates the driving profile betweenselected speeds.Symbol: 1 = Input is active0 = Input is not activeX = Setting has no effect or don’t careb) Input coded set speed selection LF.02 = d SPdX2A.10 X2A.11 X2A.12 X2A.13Speed =0 0 0 0 0SLeveling 1 0 x xS High Leveling 0 1 x xS Intermediate 1 1 x xSHigh 0 0 1 xS Inspection 0 0 0 1A unipolar analog signal is connected to the terminalsX2A.1(+) and X2A.2 (-). Terminals X2A.3 and X2A.4 can beused for pre-torque input. Additionally with this setting theanalog output (X2A.5) for motor speed becomes unipolaras well.0 ... 10V = 0 ... max. system speed (LF.20)Terminals X2A.14 and X2A.15 are used to select directionand activate the start and stop routine. The directions belowmust be followed in the exact sequence they are listed:Start: 1.) Enable on X2A.16=on2.) “Direction” input terminal (X2A.14 = onor X2A.15 = on)3.) Drive commences current check andmagnetizes the motor when ready it willactivate the DRO output X2A.27...29.4.) Give analog speed signalStop: 1.) Analog signal => 0V2.) Terminal X2A.14 / X2A.15 = off3.) Enable X2A.16=off after the sum of thetimes adjusted in LF.78 and LF.79.a) Analog set speed selection LF.02 = AbSPdParameter Description - Basic Set Up