816. Parameter Description6.1 US-ParametersPasswordWith different passwords different parameter groups can be accessedfor advanced programming.By selecting LoAd and pressing ENTER, all the LF parametersare returned to the factory default values. Note the display willautomatically change to show the value of LF.99 upon successfulloading of the default values.Adjustment value: LoAd = reset all LF parametersDisplayed responses: PASS = default successfulbdPAS = default not successfulLoad defaultsBy selecting LoAd and pressing ENTER, the selected confi gurationfile in US.10 and all the existing LF parameter values will be loadedinto the drive. Note: if the confi guration is changed in US.10, the LFparameter values are returned to the factory default values. In thiscase, this should be done before any programming of the drive iscarried out as all parameters will be cleared. The display will changeautomatically to LF.99 upon successful loading of the confi guration.The process may take several seconds.Adjustment value: LoAd = Load Confi gurationDisplayed responses: Pro9 = Loading confi gurationPASS = Load successfulbdPAS = Load not successfulLoad configurationThis parameter allows the user to select which mode the drive willoperate in. The possibilities are closed loop induction motor, closedloop permanent magnet motor, and low speed gearless modes. Selectfrom the list below and then load the confi guration file into the drivethrough parameter US.4.Adjustment value: ICLSd = Closed loop inductionI9LSS = Closed loop induction gearlessPCLSd = Closed loop permanent magnetP9LSS = Closed loop permanent magnetgearlessSelect configurationParameter Description - Basic Set Up