EN4. CONTROL PANEL X 37FastMig X 450 power source features X 37 control panel with a clear and logical LCD menudisplay. The menu allows the operator to refine, adapt and manage the arc process and systemfunction before, during and after welding.The following information details control panel layout, button functions, operation and set-up. The menu options and their descriptions are listed for each menu command.4.1 Layout and button functionsMENUCHANNELINFO USER WF#F1 F2 F3 X 37W0072381. 4.5.6.2. 7.3.8.1. Power on button• Long press (5 sec) switches the panel on or off.• Short press returns the panel to default initial view (channel information).NOTE! This button connects power to the control panel. Use the main switch on the front of thepower source to switch the power source on or off.2. Welding channel selection buttonsFastMig X 450 offers 100 memory channels for you to store your frequently used welding jobs.• To browse memory channels, press + and – buttons.• To store a new welding job to an empty channel, press the soft key under the displaytext NEW.3. MENU buttonThis button takes you to the main menu list. Proceed following the instructions on screen.X 37 main menu listEdit Channel Make changes to existing welding channelUser Identification Selecti one user out of tenWeld Data Check out the values of the last weldSystem Config Menu Show device configuration and informationLanguage Select your menu languageSelect Feeder (WF#) Select another parallel wire feeder as a setup targetMMA/CC/CV Mode Activate MMA welding, or use CC or CV mode for ArcFeed or MasterTigLT 25011© Kemppi Oy / 1312