EN4.3 Welding parametersMIGWFSpeed 0.7…25 m/min Sets the wire feed speed.Changes by steps of 0.05, when WFSpeed < 5 m/min,and by 0.1, when WFSpeed > 5 m/minWFS-Max Sets the limit for maximum WFSpeedWFS-Min Sets the limit for minimum WFSpeedVoltage 8…50 V Step: 0.1 Controls the length of the arcVoltageMax Sets the limit for maximum voltage valueVoltageMin Sets the limit for minimum voltage valueDynamics -9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. Thelower the value the softer the arc is. The higher thevalue the rougher the arc is.1-MIGWFSpeed 0.7…25 m/min * Sets the wire feed speed.Changes by steps of 0.05, when WFSpeed < 5 m/min, and by 0.1, when WFSpeed > 5 m/minWFS-Max Sets the limit for maximum WFSpeedWFS-Min Sets the limit for minimum WFSpeedFineTuning -9…+9 Factory setting is 0( = curve point)Adjusts the arc voltage of the curve (arc length)within certain limitsFineTuningMax -9…+9 Step: 0.5 Sets the limit for maximum arc lengthFineTuningMin -9…+9 Step: 0.5 Sets the limit for minimum arc lengthDynamics -9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. Thelower the value the softer the arc is. The higher thevalue the rougher the arc is.PULSE MIGWFSpeed 0.7…25 m/min * Sets the wire feed speed.Changes by steps of 0.05, when WFSpeed< 5 m/min, and by 0.1, when WFSpeed > 5 m/minWFS-Max Sets the limit for maximum WFSpeedWFS-Min Sets the limit for minimum WFSpeedFineTuning -9…+9 Factory setting is 0( = curve point)Adjusts the base current of the curve (arc length) incertain limitsFineTuningMax -9…+9 Step: 0.5 Sets the limit for maximum arc lengthFineTuningMin -9 ... +9 Step: 0.5 Sets the limit for minimum arc lengthDynamics -9…+9 Factory setting is 0 Controls the short circuit behaviour of the arc. Thelower the value the softer the arc is. The higher thevalue the rougher the arc is.Pulse Current -10…+15% Factory settingis 0 %Reduces (–) or raises (+) the pulse current of thecurveFastMig X 45014