ENCC PROCESSCurrent 10…450 A Welding currentCurrentMax 10…450 A Set the limit for maximum current valueCurrentMin 10…450 A Set the limit for minimum current valueDynamics -9…+9 Factory settingis 0Controls the short circuit behaviour of the arc. Thelower the value the softer the arc is. The higherthe value the rougher the arc is.StartPower -9…+9 Factory settingis 0Adjusts arc ignitionCV PROCESSVoltage 10…50 V Welding voltageVoltageMax 10…50 V Set the limit for maximum voltage valueVoltageMin 10…50 V Set the limit for minimum voltage valueDynamics -9…+9 Factory settingis 0Controls the short circuit behaviour of the arc. Thelower the value the softer the arc is. The higherthe value the rougher the arc is.StartPower -9…+9 Factory settingis 0Adjusts arc ignition4.4 Welding functionsWISEROOT+ AND OTHER PROCESSES2T/4T 2T, 4T,MATCHLOG, USERFactory setting is USER (userchooses the switching logic)Sets switching logicHotStart ON, OFF, USER Factory setting is USER (userchooses ON or OFF)HotStartLevel -50…+100 % Step: 1Factory setting 40%Hot 2T Time 0…9.9 s Step: 0.1Factory setting is 1.2 sCraterFill ON, OFF, USER Factory setting is USER (userchooses ON or OFF)CraterStart 10…250 % Factory setting is 100% Sets the level of the curve where thecrater filling will startCraterFillEnd 10…250 %, nothigher than startStep: 1Factory setting is 30%Sets the level of the curve where thecrater filling will end.CraterTime 0.0…10.0 s Step: 0.1.Factory setting is 1.0 sSets slope time for crate fillingCrater 4T Timer On, OFF Factory setting is OFF ON: if 4T is selected, crater filling willlast at least time that has been adjustedby CraterTime or as long as trigger ispressed.OFF: if 4T is selected, crater filling willlast as long as trigger is pressed.FastMig X 45016