1-46 (No.RA018)4.9 Transmitter Section5.RTCCorre-citon1) Adj item:[RTC]Adjust:[****]Press [ ] keyto store the ad-justment val-ue.1) Adj item:[RTC Correction]Data: {****]Press [Apply] buttonto store the adjust-ment value.Fre-quencyCounterPanel TESTPOINT(CN709orCN710)[Paneltuningmode][], [][PC testmode][←], [→][Panel tuning mode]Press [ ] key to storethe adjustment value.[PC test mode]Press [Apply] button tostore the adjustmentvalue.Remaks:Change the adjust-ment value so thatthe frequency cur-rently displayed on“Crystal OscillationFrequency” on thePC window and thefrequency currentlydisplayed on thefrequency counterare in agreement.Item Condition Measurement Adjustment Specifications/RemarksPanel tuningmodePC test mode Test-equip-mentUnit Ter-minalUnit Parts MethodItem Condition Measurement Adjustment Specifica-tions/RemarksPanel tuningmodePC test mode Test-equip-mentUnit Ter-minalUnit Parts Method1.RampupOffset1) Adj item:[RAMPU]Adjust:[****]PTT : ONPress [ ] key tostore the adjust-ment value.1) Adj item:[Ramp Up Offset]Press [Transmit]button.Press [Apply]button to store theadjustment value.PowermeterAmmeterPanel ANT Panel [Paneltuningmode][],[][PCtestmode][←],[→][PC test mode][Automatic Adjust-ment]1) Press [Tune RumpOffset] button.2) Press [Apply All] but-ton to store the adjust-ment value after theautomatic adjustmenthas finished.[Manual Adjustment]1) Set the adjustmentvalue to “1”.2) Increase the adjust-ment value slowly whilemonitoring the offsetmonitor value.3) Set the adjustmentvalue when the offsetmonitor value exceed“50”.