1-90 (No.RA018)5. OpenSquelch[AnalogWide 5k]1) Adj item:[Aw SQL]Adjust:[***]2) Adj item:[Low1]→[Low3]→[Center2]→[High1]→[High3]SSG output:12dB SINAD levelat Analog Narrow-3dB(MOD: 1kHz/±3kHz)1) Adj item:[Open Squelch (An-alog Wide 5k)]2) Adj item:[Low1]→[Low3]→[Center2]→[High1]→[High3]SSG output:12dB SINAD level atAnalog Narrow -3dB(MOD: 1kHz/±3kHz)SSGDistor-tionmeterOscillo-scopePanel ANTUni-versalcon-nectorPanel [Panel tuning mode]After input signal fromSSG, press [ ] key tostore the adjustment val-ue.[PC test mode]After input signal fromSSG, press [Apply] buttonto store the adjustmentvalue.[AnalogWide 4k]1) Adj item:[As SQL]Adjust:[***]2) Adj item:[Low1]→[Low5]→[Center3]→[High2]→[High6]SSG output:12dB SINAD levelat Analog Narrow-3dB(MOD: 1kHz/±2.4kHz)1) Adj item:[Open Squelch (An-alog Wide 4k]2) Adj item:[Low1]→[Low5]→[Center3]→[High2]→[High6]SSG output:12dB SINAD level atAnalog Narrow -3dB(MOD: 1kHz/±2.4kHz)SSGDistor-tionmeterOscillo-scopePanel ANTUni-versalcon-nectorPanel [Panel tuning mode]After input signal fromSSG, press [ ] key tostore the adjustment val-ue.[PC test mode]After input signal fromSSG, press [Apply] buttonto store the adjustmentvalue.[AnalogNarrow]1) Adj item:[An SQL]Adjust:[***]2) Adj item:[Low1]→[Low3]→[Center2]→[High1]→[High3]SSG output:12dB SINAD levelat Analog Narrow-3dB(MOD: 1kHz/±1.5kHz)1) Adj item:[Open Squelch (An-alog Narrow)]2) Adj item:[Low1]→[Low3]→[Center2]→[High1]→[High3]SSG output:12dB SINAD level atAnalog Narrow -3dB(MOD: 1kHz/±1.5kHz)SSGDistor-tionmeterOscillo-scopePanel ANTUni-versalcon-nectorPanel [Panel tuning mode]After input signal fromSSG, press [ ] key tostore the adjustment val-ue.[PC test mode]After input signal fromSSG, press [Apply] buttonto store the adjustmentvalue.Item Condition Measurement Adjustment Specifi-cations/RemarksPanel tuning mode PC test mode Test-equip-mentUnit Ter-minalUnit Parts Method