TK-5210 (G)60ADJUSTMENTItemCondition Measurement Adjustment Specifi cations /RemarksPanel tuning mode PC test mode Test-equipment Unit Terminal Unit Parts Method12. VOX 1 1) Adj item: [VOX1]Adjust: [***]AG: 1kHz/45mV atMIC terminal1) Adj item: [VOX1]AG: 1kHz/45mV atMIC terminalAG Panel UniversalconnectorPanel [Panel tuning mode]After apply signalfrom AG, press [B]key to store theadjustment value.[PC test mode]After apply signalfrom AG, press [Ap-ply] button to storethe adjustmentvalue.13. VOX 10 1) Adj item: [VOX10]Adjust: [***]AG: 1kHz/3mV atMIC terminal1) Adj item: [VOX10]AG: 1kHz/3mV atMIC terminal14. BatteryWarningLevelwriting1) Adj item: [Battery]Adjust: [***]PTT: ON1) Adj item: [BatteryWarning Level]PTT: Press [Trans-mit] button.PowermeterDVMPanel ANTBATTterminalPanel [Panel tuning mode]After pressing thePTT switch, confirmthat one predeter-mined numeric inthe range 1 to 256appears and thenpress [B] key Thatnumeric will bestored in memory.[PC test mode]After pressing thePTT switch, confirmthat one predeter-mined numeric inthe range 1 to 256appears and thenpress [Apply] keyThat numeric will bestored in memory.BATT terminalvoltage: 5.8V15. BatteryWarningLevelcheck[Panel test mode]1) CH-Sig: 1-1BATT terminal volt-age: 6.0VPTT: ON1) Test Channel: Chan-nel 1Test SignalingMode: AnalogSignaling: 1BATT terminal volt-age: 6.0VPTT: Press [Trans-mit] button.The transceivercan transmit withcausing the LED toblink.