TK-5210 (G)61ADJUSTMENT*2: Necessary adjustment and order for each signaling is shown as below.Mode Signaling Necessary adjustment and orderWide NarrowAnalogAudio 1. Balance adjust2. Analog Deviation adjust [Wide]1. Balance adjust2. Analog Deviation adjust [Narrow]QT1. Balance adjust2. Analog Deviation adjust [Wide]3. QT Fine Deviation adjust [Wide]1. Balance adjust2. Analog Deviation adjust [Narrow]3. QT Fine Deviation adjust [Narrow]DQT1. Balance adjust2. Analog Deviation adjust [Wide]3. DQT Fine Deviation adjust [Wide]1. Balance adjust2. Analog Deviation adjust [Narrow]3. DQT Fine Deviation adjust [Narrow]DTMF1. Balance adjust2. Analog Deviation adjust [Wide]3. DTMF Deviation adjust [Wide]1. Balance adjust2. Analog Deviation adjust [Narrow]3. DTMF Deviation adjust [Narrow]Single TONE1. Balance adjust2. Analog Deviation adjust [Wide]3. TONE Deviation adjust [Wide]1. Balance adjust2. Analog Deviation adjust [Narrow]3. TONE Deviation adjust [Narrow]MSK1. Balance adjust2. Analog Deviation adjust [Wide]3. MKS Deviation adjust [Wide]1. Balance adjust2. Analog Deviation adjust [Narrow]3. MSK Deviation adjust [Narrow]P25 – 1. Balance adjust2. P25 High Deviation adjustReceiver SectionItemCondition Measurement Adjustment Specifications /RemarksPanel tuning mode PC test mode Test-equipment Unit Terminal Unit Parts Method1. AF levelsetting[Panel test mode]1) CH-Sig: 1-1SSG output:–47dBm (1mV)(MOD: 1kHz/±1.5kHz)[Concentric SW]: B1) Test Channel: Chan-nel 1Test SignalingMode: AnalogBandwith:2.5kHz/12.5kHzSignaling: 1SSG output:–47dBm (1mV)(MOD: 1kHz/±1.5kHz)SSGDVMAF VTVMDummyloadPanel ANTUniversalconnectorPanel VolumeknobTurn the Volumeknob to obtain0.63V AF output.0.63V±0.1V2 . Sensitivitycheck1) CH-Sig: 2-1SSG outputWide: –118dBm(0.28μV)(MOD: 1kHz/±3kHz)Narrow: –118dBm(0.28μV)(MOD: 1kHz/±1.5kHz)2) CH-Sig: 6-1Other conditionsare same as 1).1) Test Channel: Chan-nel 2Test SignalingMode: AnalogSignaling: 1SSG outputWide: –118dBm(0.28μV)(MOD: 1kHz/±3kHz)Narrow: –118dBm(0.28μV)(MOD: 1kHz/±1.5kHz)2) Test Channel: Chan-nel 6Other conditionsare same as 1).SSGAF VTVMOscilloscopePanel ANTUniversalconnectorCheck 12dB SINAD ormore