Version: 1.01 USA Function Reference (FUNC) 4820 FUNCTION PORTMonitor OnThe Signalling Decode function is disabled when the signal is applied to the PF [Monitor On] inputport. When a signal is detected with the Down Edge, you cannot switch the monitor Off after thisfunction is once enabled. It should be used with Monitor Off function.Monitor On/OffThe Signalling Decode function is switched disable and enable when the signal is applied to thePF [Monitor On/Off] input port. You can use this function only when the signal is detected with theDown Edge. (Refer to 20.2.1 Trigger Detection for Auxiliary Input Ports.)Multi-table SubTKR-750/850/751/851 switches the signalling specified with the Multi-table Select to the Sub-table signalling when a signal is applied to the PF [Multi-table Sub] input port. (Refer to 20.1 AUXI/O Function.)When the signal is detected with the Down Edge, you cannot return to the Main-table after theSub-table is once selected. So it should be used with Multi-Table Main function.Multi-table MainTKR-750/850/751/851 switches the signalling specified with the Multi-table Select to the Main-table when a signal is applied to the PF [Multi-table Main] input port. (Refer to 20.1 AUX I/OFunction.)When the signal is detected with the Down Edge, you cannot switch to the Sub-table after theMain-table is once selected. So it should be used with Multi-Table Sub function.Multi-tableMain/SubTKR-750/850/751/851 switches Main/Sub for the signalling specified with the Multi-table Selectwhen a signal is applied to the PF [Multi-table Main/Sub] input port. (Refer to 20.1 AUX I/OFunction.)You can use this function only when the signal is detected with the Down Edge. (Refer to 20.2.1Trigger Detection for Auxiliary Input Ports.)QT/DQT Decode DisableThe QT/DQT Decode function is disabled when the signal is applied to the PF [QT/DQT DecodeDisable] input port. When a signal is detected with the Down Edge, you cannot switch the QT/DQT Decode function On after this function is once enabled. So it should be used with enablefunction.This function is available even when TKR-750/850/751/851 is performing the repeat operation.QT/DQT Decode EnableThe QT/DQT Decode function is enabled when a signal is applied to the PF [QT/DQT DecodeEnable] input port. So it should be used with Disable function.When the signal is detected with the Down Edge, you cannot switch the QT/DQT Decode functionOff after this function is once enabled.QT/DQT Decode Disable/EnableThe QT/DQT Decode function is switched disable and enable when a signal is applied to the PF[QT/DQT Encode Disable/Enable] input port. You can use this function only when the signal isdetected with the Down Edge. (Refer to 20.2.1 Trigger Detection for Auxiliary Input Ports.)QT/DQT Encode DisableThe QT/DQT Encode function is disabled when a signal is applied to the PF [QT/DQT EncodeDisable] input port. When the signal is detected with the Down Edge, you cannot switch the QT/DQT Encode On after this function is once enabled. So it should be used with Enable function.QT/DQT Encode EnableThe QT/DQT Encode function is enabled when a signal is applied to the PF [QT/DQT EncodeEnable] input port. When the signal is detected with the Down Edge, you cannot switch the QT/DQT Encode Off after this function is once enabled. So it should be used with Disable function.QT/DQT Encode Disable/EnableThe QT/DQT Encode function is switched disable and enable when a signal is applied to the PF[QT/DQT Encode Disable/Enable] input port. You can use this function only when the signal isdetected with the Down Edge. (Refer to 20.2.1 Trigger Detection for Auxiliary Input Ports.)Repeat DisableThe Repeat operation is disabled when a signal is applied to the PF [Repeat Disable] input port.You cannot configure this function if no channel is configured to the repeat operation.When the signal is detected with the Down Edge, you cannot enable the Repeat operation afterthis function is once enabled. It should be used with Enable function.Repeat EnableThe Repeat operation is enabled when a signal is applied to the PF [Repeat Enable] input port.You cannot configure this function if no channel is configured to the repeat operation.When the signal is detected with the Down Edge, you cannot disable the repeat operation afterthis function is once enabled. It should be used with Disable function.Repeat Disable/EnableThe repeat operation is switched enable and disable when a signal is applied to the PF [RepeatDisable/Enable] input port.You cannot configure this function if no channel is configured to the repeat operation. You can usethis function only when the signal is detected with the Down Edge. (Refer to 20.2.1 TriggerDetection for Auxiliary Input Ports.)Reset The TKR-750/850/751/851 resets the operations and returns to the default value when a signal isapplied to the PF [Reset] input port.Scan OffThe Scan is disabled when a signal is applied to the PF [Scan Off] input port.When a signal is detected with the Down Edge, you cannot enable the Scan after this function isonce enabled. So it should be used with On function.Function Name Description