Keysight E8402A, E8404A C-Size Mainframes User and Service Guide 157STATus Subsystem Programming the Enhanced MonitorSTATus:SCONdition?The STATus:SCONdition? query returns two integers indicating the pass/failcondition in the Enhanced Monitor. The integers are the sum of the decimalvalues of the bits that are set. A returned value of 0 in both integers indicatesthat there are no failures. A value of 1 (one) in a bit indicates that thecorresponding present condition has failed. Unused bits return 0. Reading thecondition does not clear the failure.Returned DataType Range Default DecimalWeightDescriptionuint32 0 to2147483647none 12481632641282565121024204840968192163843276865536131072262144524288104857620971524194304838860816777216335544326710886413421772826843545653687091210737418242147483648Bit 0: Maintenance Counter ExpiredBit 1: +5V Power Supply Voltage out of limitBit 2: +12V Power Supply Voltage out of limitBit 3: -12V Power Supply Voltage out of limitBit 4: +24V Power Supply Voltage out of limitBit 5: -24V Power Supply Voltage out of limitBit 6: -5.2V Power Supply Voltage out of limitBit 7: -2V Power Supply Voltage out of limitBit 8: +5V STby Power Supply Voltage out of limitBit 9: +5V Power Supply Current out of limitBit 10: +12V Power Supply Current out of limitBit 11: -12V Power Supply Current out of limitBit 12: +24V Power Supply Current out of limitBit 13: -24V Power Supply Current out of limitBit 14: -5.2V Power Supply Current out of limitBit 15: -2V Power Supply Current out of limitBit 16: Slot 0 Temperature over limitBit 17: Slot 1 Temperature over limitBit 18: Slot 2 Temperature over limitBit 19: Slot 3 Temperature over limitBit 20: Slot 4 Temperature over limitBit 21: Slot 5 Temperature over limitBit 22: Slot 6 Temperature over limitBit 23: Slot 7 Temperature over limitBit 24: Slot 8 Temperature over limitBit 25: Slot 9 Temperature over limitBit 26: Slot 10 Temperature over limitBit 27: Slot 11 Temperature over limitBit 28: Slot 12 Temperature over limitBit 29: Ambient Temperature over limitBit 30 Power Supply Temperature over limitBit 31: Not Used; set to 0.