8: Setup Mode: Channel ConfigurationXPress DR+ User Guide 52Table 8-3. Flow Control OptionsFlow Control Option HexNo flow control 00XON/XOFF flow control 01Hardware handshake with RTS/CTS lines 02XON/XOFF pass characters to host 05Port NumberThe setting represents the source port number in TCP connections. It is the number thatidentifies the channel for remote initiating connections.Port No (10001) ? _The default setting for port 1 is 10001. The default setting for Port 2 is 10002. The rangeis 1-65535, except for the following reserved port numbers:Table 8-4. Reserved Port NumbersWarning: We recommend that you not use the reserved port numbers forthis setting as incorrect operation may result.Use Port 0 for the outgoing local port to change with each connection. The port range is50,000 to 59,999. Each subsequent connection increments the number by 1 (it wrapsback around to 50,000).Only use this automatic port increment feature to initiate a connection using TCP. Set theport to a non-zero value when the unit is in a passive mode or when using UDP insteadof TCP.Connect ModeConnect Mode defines how the unit makes a connection, and how it reacts to incomingconnections over the network.ConnectMode (C0) ? _Enter Connect Mode options in hexadecimal notation.Port Numbers Reserved for1 – 1024 Reserved (well known ports)9999 Telnet setup14000-14009 Reserved for Redirector30704 Reserved (77F0h)30718 Reserved (77FEh)