8: Setup Mode: Channel ConfigurationXPress DR+ User Guide 62Send Characters If 2-Byte Send Character Sequence is enabled, the unit interprets thesendchars as a 2-byte sequence; if this option is not enabled, the unit interpretsthem independently. If Send Immediately After Characters is not set, any characters already in theserial buffer are included in the transmission after a "transmit" condition is found.If this option is set, the unit sends immediately after recognizing the transmitcondition (sendchar or timeout).Note: A transmission might occur if status information needs to be exchanged oran acknowledgment needs to be sent.DisConnTime (Inactivity Timeout)Use this parameter to set an inactivity timeout. The unit drops the connection if there isno activity on the serial line before the set time expires. Enter time in the format mm:ss,where m is the number of minutes and s is the number of seconds.DisConnTime (0: 0) ?:To disable the inactivity timeout, enter 00:00. Range is 0 (disabled) to 5999 seconds (99minutes, 59 seconds). Default setting is 0.Send CharactersEnter up to two characters in hexadecimal representation in sendchar.SendChar 1 ( 0) ? _SendChar 2 ( 0) ? _If the unit receives a character on the serial line that matches one of these characters, itsends the character immediately, along with any awaiting characters, to the TCPconnection. This action minimizes the response time for specific protocol characters onthe serial line (for example, ETX, EOT). Setting the first sendchar to 00 disables therecognition of the characters. Alternatively, the unit can interpret two characters as asequence (see Pack Control on page 61).Telnet Terminal TypeThis parameter displays only if you enabled the terminal type option in Disconnect Mode.With this option enabled, you can use the terminal name for the Telnet terminal type.Enter only one name.With terminal type option enabled, the unit also reacts to the EOR (end of record) andbinary options, useful for applications like terminal emulation to IBM hosts.Channel (Port) PasswordThis parameter appears only if the channel (port) password option is enabled inDisconnect Mode. With this option enabled, you can set a password on the serial port.