15-14 9010F Fast15.2.3 Limit Each emission standard has one or more limits the User shall comply with.The PMM 9010F receiver has the possibility to load and activate one limitwith a simple push of a button.The preloaded standard limits refer to the most popular EMC emissionstandards: CISPR22, CISPR14 and CISPR11.Other limits – or any custom designed limit – can be created, managed,selected and loaded through the PMM 9010F Software Utility running on aPC (and the test, of course, shall be handled via the PC software).These additional custom limits cannot be stored in the memory of the PMM9010F, but only in the one of the PC where the 9010FSW Utility is running.The limits are shown on the scan display and they appear like a thin blackline when the Smart Detector function is not enabled, while one of themappears in bold black when the Smart Detector function is active.By pressing the NONE button all limits are deactivated.15.2.4 Display Pressing the Display button it is possible to set two parameters: thevisualized Dynamic range(chosen between 80, 100 and 120dB) and theReference Level, that can be increased or reduced by steps of 5dB withinthe range +80 dBμV to 135 dBμV (-25 to +30 dBm); see also 4.2.