CHAPTER 8 8-BIT TIMER/EVENT COUNTER 5User’s Manual U16896EJ2V0UD3128.4.8 Cautions(1) Error on starting timerAn error of up to 1 clock occurs before the match signal is generated after the timer has been started. This isbecause the TM5n register is started asynchronously to the count pulse.Figure 8-8. Count Start Timing of TM5n Register00HTimer start01H 02H 03H 04HCount pulseTM5n count valueRemark n = 0, 1